Bosch Oven Error Code E302

Control module too hot

Control module too hot — temperature sensor on the control module detects temperature higher than limit value; control turns off heating elements and fan defaults to high speed.

First step from the service manual

If cooling fan is not operating, check connections to the fan and the control module (see Small Load Schematic). If cooling fan is operating, check element operation, check for air obstruction or damaged upper/lower ventilation trims, and check for stuck relays.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.