Bosch Refrigerator Error Code 1011
Inverter error
Inverter error: IGBT short circuit or open circuit
First step from the service manual
Change inverter
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for 1011.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What 1011 means on a Bosch refrigerator
Error code 1011 on a Bosch refrigerator indicates an inverter fault specifically related to the IGBT (Insulated Gate Bipolar Transistor) within the inverter board. The IGBT is a power switching component that controls the variable-speed compressor motor by modulating voltage and current at high frequency. When the refrigerator's control system detects that the IGBT is either shorted (allowing uncontrolled current flow) or open-circuited (blocking all current flow), it triggers this fault code and typically shuts down compressor operation to prevent further damage.
The inverter board itself converts DC voltage to the controlled AC output required to run the linear or variable-speed compressor. An IGBT short circuit usually results from thermal overload, voltage spikes, or component degradation over time, and may produce visible signs such as burn marks or a burnt smell on the board. An open circuit failure, by contrast, means the transistor can no longer conduct at all, which also halts compressor function entirely. Both conditions result in the refrigerator losing its ability to cool.
Because the IGBT is integrated directly onto the inverter board assembly and is not typically serviced as a standalone component in the field, the standard corrective action is full inverter board replacement. Before replacing the board, technicians should verify that the compressor windings are not shorted, as a failed compressor can damage a new inverter board immediately upon installation.
Source: manufacturer service documentation.
Common causes of 1011
- 01
Failed IGBT on the inverter board
Part replacementThe IGBT transistor on the inverter board has failed due to thermal stress, age, or a voltage surge. This is the direct cause identified by error 1011 and requires inverter board replacement.
- 02
Shorted or damaged compressor windings
Part replacementA compressor with shorted windings can draw excessive current through the inverter, destroying the IGBT. Check compressor winding resistance before installing a new inverter board.
- 03
Power surge or voltage spike
Part replacementA sudden spike in supply voltage can instantly damage the IGBT beyond recovery. Inspect for signs of electrical damage on the board and consider surge protection going forward.
- 04
Inverter board overheating
Wiring / connectionPoor ventilation around the inverter board can cause repeated thermal stress on the IGBT, leading to eventual failure. Check that condenser fan operation and airflow paths are unobstructed.
- 05
Loose or corroded wiring connections
Wiring / connectionIntermittent connections between the inverter board and compressor can cause irregular current loads that stress and eventually fail the IGBT. Inspect all connector pins and harness terminals before replacing the board.
Frequently asked questions about 1011
What does 1011 mean on a Bosch refrigerator?
Can I fix error code 1011 on my Bosch refrigerator myself?
Is it safe to use my Bosch refrigerator while it shows error code 1011?
How much does it cost to repair a Bosch refrigerator with error code 1011?
Will resetting my Bosch refrigerator clear error code 1011?
78,000+ service manuals · 160,000+ error codes · 55+ brands