Bradford White Water Heater Error Code Solid ON (WR Electronic)
White Rodgers Electronic
White Rodgers Electronic: Not an error; indicates that the control is in shutdown mode. Setpoint knob was recently turned to OFF.
First step from the service manual
Wait until LED goes out before attempting to relight.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for Solid ON (WR Electronic).
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What Solid ON (WR Electronic) means on a Bradford White water heater
The Solid ON LED condition on a Bradford White water heater equipped with a White Rodgers electronic gas control is not a fault or error code. Instead, it indicates that the control has entered a deliberate shutdown mode. This state is triggered when the setpoint knob is turned to the OFF position. The White Rodgers electronic control module monitors the knob position and, upon detecting the OFF setting, places the gas valve and ignition system in a controlled shutdown state. The LED remains continuously illuminated during this period as a status indicator, signaling that the shutdown sequence has been initiated but the control has not yet fully de-energized.
During shutdown mode, the control is in a transitional state between active operation and a fully powered-down condition. Attempting to relight the water heater or turn the setpoint knob back to an operating temperature before the LED extinguishes can interfere with this sequence. The White Rodgers control requires time to complete its internal shutdown cycle and reset its logic before it is ready to accept a new startup command. The LED going dark confirms that the control has finished its shutdown routine and is ready for a normal relight procedure.
This condition is entirely normal and does not indicate any component failure, wiring fault, or safety lockout. No parts replacement is needed. The correct response is simply to wait for the LED to go out completely before proceeding with the standard relight procedure outlined on the water heater's label. This typically takes only a short time after the knob is turned to OFF.
Source: manufacturer service documentation.
Common causes of Solid ON (WR Electronic)
- 01
Setpoint knob turned to OFF position
Wiring / connectionThe most direct cause of this condition is the temperature setpoint knob being rotated to the OFF setting. The White Rodgers electronic control enters shutdown mode immediately when this action is taken, and the solid LED confirms it is processing the shutdown.
- 02
Accidental knob movement
Wiring / connectionThe setpoint knob may have been inadvertently bumped or rotated to the OFF position during cleaning, maintenance, or work near the water heater. Inspect the knob position to confirm this is the case.
- 03
Intentional shutdown for maintenance
Wiring / connectionA technician or homeowner may have turned the control to OFF before servicing the unit or during a water heater inspection, and the control is now completing its shutdown cycle before being restarted.
Frequently asked questions about Solid ON (WR Electronic)
What does Solid ON (WR Electronic) mean on a Bradford White water_heater?
How do I fix the Solid ON LED condition on my Bradford White water heater?
Is the Solid ON LED on my Bradford White water heater a safety issue?
Will resetting the control clear the Solid ON condition?
How much does it cost to repair the Solid ON condition on a Bradford White water heater?
78,000+ service manuals · 160,000+ error codes · 55+ brands