Error code reference

Café Refrigerator Error Codes

72 error codes documented with diagnostic procedures.

Have your model number? Get codes specific to your unit.
0001Refrigerator (FF) thermistor reading out of range.0003Freezer (FZ) thermistor reading out of range.0004Freezer (FZ) evaporator thermistor reading out of range.0006Refrigerator (FF) evaporator thermistor reading out of range.0008Ambient temperature reading out of range.0009Humidity sensor reading out of range.0010Ice maker mold body thermistor reading out of range.0100Freezer (FZ) fan feedback missing when fan is running.0101Freezer (FZ) fan feedback present when fan is off.0102Freezer (FZ) fan cannot reach target RPM.0103Condenser fan feedback missing when fan is running.0104Condenser fan feedback present when fan is off.0105Condenser fan cannot reach target RPM.0106Refrigerator (FF) fan feedback missing when fan is running.0107Refrigerator (FF) fan feedback present when fan is off.0108Refrigerator (FF) fan cannot reach target RPM.0109Ice box fan feedback missing when fan is running.0110Ice box fan feedback present when fan is off.0111Ice box fan cannot reach target RPM.0200Freezer defrost heater on for max time.0201Refrigerator defrost heater on for max time.0202Five consecutive freezer abnormal defrosts.0203Five consecutive refrigerator abnormal defrosts.0300Excessive compressor run time.0301Cooling system was on and the compressor remained off for 3-hours.0303Refrigerator temperature exceeded (setpoint + 20°F).0304Freezer temperature exceeded (setpoint + 20°F).03083-way valve lost.0311Convertible drawer damper stuck closed.0312Convertible drawer damper stuck open.0313Convertible drawer temperature exceeded (setpoint + 20°F).0314Convertible drawer freezing when set to warm.03153-way valve cooling not detected in refrigerator evaporator.03163-way valve cooling not detected in freezer evaporator.0400DC voltage out of range.0403Main control board software fault (replace board).0404Main control board hardware fault (replace board).0501Flow meter signal missing.0502Flow meter pulsing with no water dispense.0503Ice/water stops dispensing based on time (7-minute time out).0507Paddle switch input missing when main board has received a message it was pressed.0508Paddle switch input present when main board has not received a message it was pressed.0511Ice mold temperature invalid.0512Ice box thermistor temperature invalid.0515Door board relay driver is shorted (replace door board).0601Ice maker harvest > 10-minutes.06023 out of last 10 ice maker harvests were > 10-minutes.0603Ice maker harvest not complete after 30-minutes.0604Ice maker no water supply detected.0605Ice maker continues to sense a full bucket after an ice dispense.0700Stuck keys on dispenser board.0713A refrigerator door opens for 15 minutes without being closed.0714A refrigerator door opens for 60 minutes in the last 24-hours.0715100 left door openings in the last 24-hours.0716100 right door openings in the last 24-hours.0717Freezer drawer open for 15 minutes continuously.0718Freezer drawer open for 60 total minutes in the last 24-hours.0719100 freezer drawer openings in the last 24-hours.0721AutoFill sensors detect an object present over several hours; sensors may be dirty and…0722AutoFill initialization failed.0723Capacitive touch controlled reset.0726Convertible drawer opens for 15-minutes without closing.0727Convertible drawer opens for 60-minutes in the last 24-hours.0728100 convertible drawer openings in the last 24-hours.0729Stuck keys on convertible drawer board.0731Convertible drawer board communication error.0732Door board communication error.0733Dispenser board communication error.0737AutoFill termination by no water level change.0738AutoFill terminated by keypad before fill completed.0739AutoFill terminated by target removal before fill completed.0740AutoFill terminated by EMI noise.

Get the full diagnostic procedure for any code

Step-by-step tests, expected values, wiring diagram references, and verified part numbers.

Get Started $9.95 3-day pass

$29/month for all brands and Max diagnostics, with 70 Max messages a day. Plus applicable tax.