Error code reference
Electrolux Refrigerator Error Code E4
Ice maker harvest motor stuck in fill position (cannot move from Fill to Freeze).
Ice maker harvest motor stuck in fill position (cannot move from Fill to Freeze).
First step from the service manual
1
See Flow Chart Test #63C.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
MyPros+ Max
Get the full diagnostic procedure for E4.
- ✓Step-by-step tests with expected resistance, voltage, and continuity values
- ✓Wiring diagram references and connector pinouts from the OEM service manual
- ✓Verified part numbers when replacement is required
Get the full procedure→
$29/month · Cancel anytime · Or $9.95 3-day pass
M+
M+ Max·Electrolux Refrigerator
E4 on my Electrolux Refrigerator
M+
Ice maker harvest motor stuck in fill position
From Service Manual 652622, p.34:
1.See Flow Chart Test #63C.
2.Measure the inlet valve coil resistance at the valve connector. Expected: 1,000 to 1,200 ohms per coil at room temperature.
3.Verify static water supply pressure at the inlet hose. Below 20 psi or fluctuating supply commonly triggers fill-timeout faults.
Part 5304528407
Water inlet valve
Related Electrolux refrigerator codes
All Electrolux refrigerator codes →- _ _Incorrect voltage detected (127V unit connected to 220V) on…
- 1st LED blinkingFault in the temperature sensor (sensor disconnected or…
- 2Thermistor is open (displayed during start-up test or…
- 21Open NTC thermistor for the chamber (drawer) NTC on Perfect…
- 22Open NTC thermistor for the freezer NTC on Perfect…
- 2nd LED blinkingFault in the defrost sensor (sensor disconnected or…
- 2XOpen NTC where X is
- 3Thermistor sensor is shorted (displayed during start-up…
View all 92 Electrolux refrigerator codes
- 31Shorted NTC thermistor for the chamber (drawer) NTC on…
- 32Shorted NTC thermistor for the freezer NTC on Perfect…
- 38Freezer sensor shorted.
- 3XShorted NTC where X is
- 4Damper failure on Side-by-Side refrigerators equipped with…
- 41FF (Fresh Food) sensor open or shorted (see test 11/12…
- 5Any combination of two or more sensor/interface failures…
- 5HFresh Food Ice Maker tray thermistor short circuit detected.
- 91Shorted ON/OFF key/button on Perfect Temperature Drawer.
- 92Shorted + key/button on Perfect Temperature Drawer.
- 93Shorted C/F key/button on Perfect Temperature Drawer.
- 94Shorted
- 95Shorted control lock key/button on Perfect Temperature…
- 96Shorted down arrow key/button on Perfect Temperature Drawer.
- 97Shorted up arrow key/button on Perfect Temperature Drawer.
- 9XShorted key/button where X is
- AFAir filter replacement reminder
- board incompatibilityIndicates incompatibility between the power control board…
- CDClose the door to start dishwasher operation (also…
- CEIce maker communication lost between main board and ice…
- CFCommunication failure between main board and user interface…
- CLClose the door to start dishwasher operation (also…
- cooler sensor faultCooler air temperature sensor signal is out of range…
- dAMalfunctioning of freezer air temperature sensor (signal…
- dEIncompatibility between the electronic boards (power board…
- dFManual defrost mode is active (d and F displayed in freezer…
- EGeneral error indication
- E/FEvaporator fan motor test failed during startup self-test…
- E0No error detected by the system.
- E1Ice maker mold heater failure (Finger Evaporator ice maker).
- E11Dishwasher drain valve issue; insulation strip in the drain…
- E2Room temperature sensor damaged (installed on the display…
- E3Evaporator mounted sensor shorted circuit detected.
- E5Showroom Mode is active; compressor, fan, and defrost…
- E6Ice maker harvest motor stuck in intermediate position…
- E7Stuck key detected (keypress read for longer than 30…
- E8Shorted thermistor condition; the temperature sensor…
- E9Open thermistor detected
- EdShorted or open defrost thermistor.
- eeprom errorEEPROM parameter writing/reading error on the electronic…
- ELShorted or open lower thermistor (also the default error…
- ErIce maker communication error or incompatible protocols…
- EUShorted or open upper thermistor.
- FEEV (Electronic Expansion Valve) test failed; temperature…
- F1Refrigerator compartment air sensor defective.
- F2Refrigerator compartment evaporator sensor defective.
- F3Freezer compartment air sensor defective.
- F4Freezer compartment evaporator sensor defective.
- F68High voltage or low voltage condition present in the power…
- F69High voltage or low voltage condition present in the power…
- FrIce maker is in Freezer Recovery Mode
- freezer sensor faultFreezer air temperature sensor signal is out of range…
- freezer temp alarmFreezer compartment temperature has reached -11°C or…
- HIndicates the HOLIDAY function is active on the cooler…
- HDThe dishwasher is in a heat delay (also displayed as HO).
- HIHigh temperature condition detected in fresh food (above…
- HI FUCL over temperature time out exceeded (Perfect Temp…
- High temp indicator blinkingSensor failure detected during operation
- HOThe dishwasher is in a heat delay (also displayed as HD).
- Ice CEIce maker communication lost with main control board.
- Ice ErIce maker IM/RAM error
- ICE t3Ice maker TH3 suction line thermistor open or shorted.
- IPIncompatible protocols between main board (PB) and ice…
- LJShow Room mode active on DF80/DF80X models; panel and…
- LOThe rinse aid in the dispenser is low; does not affect…
- LO FLCL under temperature time out exceeded (Perfect Temp…
- locPanel lock indicator on DF80/DF80X models; control panel is…
- OPFresh food temperature sensor is open circuit (displayed in…
- OP (FZ)Open freezer cavity thermistor detected.
- P2Primary sensor open circuit detected.
- P3Primary sensor shorted circuit detected.
- PFThe dishwasher control has lost power and the power has…
- PoDoor open alarm on DF80/DF80X models; one or both doors…
- rAWater reservoir empty alert on DFI80/DI80X; ice maker…
- SHFresh food sensor shorted circuit detected (displayed in…
- SH (FZ)Shorted freezer cavity thermistor detected.
- SYSystem error code displayed on the user interface.
- SY CECommunication between the User Interface and Main Board was…
- SY CFCommunication was not established between UI and Main Board…
- SY EFEvaporator fan failure detected by the main control.
- t3Ice maker TH3 suction line sensor is open or shorted…
- UFThe control is not seeing the vent fan running properly…
- UIIncorrect user interface board detected.
- UOThe control believes the vent baffle is stuck open; this…
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started →$29/month · Cancel anytime · Or $9.95 3-day pass