Frigidaire Refrigerator Error Code dr

Refrigerator door switch is defective (senses door open for more than 1 hour).

Refrigerator door switch is defective (senses door open for more than 1 hour).

First step from the service manual

Check each door switch and exchange if defective.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for dr.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What dr means on a Frigidaire refrigerator

The dr error code on a Frigidaire refrigerator indicates that the control board has detected a door open condition lasting longer than one continuous hour. The door switch system relies on small plunger-style or magnetic switches mounted in the door frame or cabinet to signal the control board whenever a door is opened or closed. When the board stops receiving a "door closed" signal for more than 60 minutes, it logs the dr fault and typically activates an alert to prevent temperature loss and excessive compressor cycling.

The most direct cause of this fault is a defective door switch that has failed in the open-circuit position, causing the board to interpret the door as perpetually open even when it is physically closed. Beyond switch failure, the wiring harness connecting the switch to the control board can develop breaks, shorts, or corroded terminals that mimic a failed switch. In some cases, the door itself may be physically misaligned or the hinge may be worn, preventing the switch actuator from making proper contact when the door closes.

Diagnosing this code starts with physically inspecting and testing each door switch. A functioning switch should show continuity when depressed and an open circuit when released. If a switch tests out of specification or fails to change state, it should be replaced. The wiring between the switch and the control board should also be inspected for damage or loose connectors before condemning the switch itself.

Source: manufacturer service documentation.

Common causes of dr

  1. 01

    Defective door switch

    Part replacement

    The door switch has failed internally and no longer sends a closed-door signal to the control board, even when the door is shut. Testing the switch for continuity while pressing the plunger will confirm whether it has failed.

  2. 02

    Worn or damaged switch actuator

    Part replacement

    The plastic tab or button that physically presses the door switch can crack or break off over time, preventing the switch from registering a closed door. Inspect the actuator on the door or door frame for visible damage.

  3. 03

    Damaged or corroded wiring harness

    Wiring / connection

    The wiring connecting the door switch to the main control board can develop breaks, pinches, or corroded terminals that interrupt the signal. Inspect the harness along its full length and check all connectors for oxidation or looseness.

  4. 04

    Door misalignment or worn hinge

    Wiring / connection

    If the refrigerator door sags or does not close squarely due to a worn hinge or improper leveling, the switch actuator may not make full contact with the switch plunger. Check that the door closes evenly and that hinges are tight and undamaged.

  5. 05

    Faulty main control board

    Part replacement

    If all door switches test correctly and the wiring harness is intact, the main control board itself may be misreading the switch input signal. This is a less common cause and should only be considered after ruling out the switches and wiring.

See the test procedure for each cause

Frequently asked questions about dr

What does dr mean on a Frigidaire refrigerator?
The dr code means the refrigerator's control board has detected that a door switch has been reporting an open-door condition for more than one hour continuously. This is typically caused by a failed door switch that no longer signals the board when the door is closed. The code can also appear if the wiring to the switch is damaged or if the door is not closing fully enough to activate the switch.
Can I fix the dr error code myself?
Many homeowners and DIYers can resolve this code by inspecting and replacing a faulty door switch, which is generally accessible without specialized tools. Start by pressing each door switch plunger manually to see if the interior light responds correctly, then test each switch for continuity with a multimeter. If a switch fails the continuity test, replacing it is straightforward on most Frigidaire models. If the switches test fine, checking the wiring harness for loose or corroded connectors is the next step.
Will resetting the refrigerator clear the dr error code?
A reset may temporarily clear the dr code from the display, but it will return if the underlying door switch problem has not been resolved. To reset the unit, you can unplug it for a few minutes and then restore power. However, until the defective switch or wiring issue is corrected, the control board will detect the fault again and reactivate the code.
Is the dr error code a safety concern?
The dr code itself is not a safety hazard, but it does indicate a condition that can affect food safety over time. If the refrigerator incorrectly believes the door is open, it may alter its cooling cycles, leading to temperature fluctuations. It is best to address the fault promptly to ensure consistent refrigerator performance and proper food preservation.
How much does it cost to fix the dr error code on a Frigidaire refrigerator?
If the repair requires only a new door switch, parts typically cost between $10 and $40 depending on the specific model. If a technician is needed for diagnosis and installation, total repair costs including labor generally range from $100 to $200. In the less common scenario where the main control board is at fault, parts and labor can bring the total to between $200 and $400.