mypros+
Error code reference

GE Microwave Error Code Lower Thermal Sensor SHORTED

The lower thermal sensor circuit is detected as shorted, indicating a failed lower thermistor.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the Lower Thermal Sensor SHORTED error code actually means

Your GE microwave has detected a problem with one of its internal temperature sensors. The sensor responsible for monitoring heat in the lower part of the microwave has failed and is sending an abnormal signal to the control board. The microwave will not operate normally until this sensor is replaced or the wiring issue is resolved.

Diagnostic procedure

The full Lower Thermal Sensor SHORTED procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check lower thermistor (red and white wires) resistance at Smart Board CN09; should be 256K ohm at room temperature.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock Lower Thermal Sensor SHORTED procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of Lower Thermal Sensor SHORTED

Ranked by how often they cause this code
  1. 1Failed lower thermistor
  2. 2Damaged wiring harness
  3. 3Moisture or contamination on the thermistor
  4. 4Loose or corroded connector at CN09
  5. 5Faulty Smart Board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about Lower Thermal Sensor SHORTED

What does Lower Thermal Sensor SHORTED mean on a GE microwave?
This error means the GE microwave's Smart Board has detected a short circuit in the lower thermistor circuit, connected at board connector CN09 via red and white wires. The thermistor normally reads approximately 256K ohms at room temperature, and a shorted condition means resistance has dropped drastically below that value. This is most often caused by a failed thermistor component but can also result from damaged wiring. The microwave will typically stop operating until the fault is resolved.
Is it safe to use the microwave while this error is active?
It is not recommended to use the microwave while this error is present. The lower thermistor is part of the thermal monitoring system that helps prevent overheating. With the sensor shorted, the control board cannot accurately track temperature in the lower cavity, which removes a layer of overheat protection. Most GE microwaves will also disable normal operation when this fault is active.
How much does it cost to repair a Lower Thermal Sensor SHORTED error on a GE microwave?
If only the thermistor needs replacement, parts typically range from around $15 to $50 depending on the specific model, with professional labor adding $75 to $150 or more. If the Smart Board is the root cause, board replacement costs can range from $100 to $250 or higher for parts alone. Getting a diagnosis first will help determine whether repair is cost-effective compared to replacing the microwave.
Can I reset the error and keep using the microwave?
Simply resetting or unplugging the microwave will not clear this error permanently because it is caused by a hardware fault, not a temporary software glitch. The Smart Board will re-detect the shorted thermistor circuit as soon as it powers up and runs its self-check. The underlying cause, whether a failed thermistor or damaged wiring, must be repaired before the error will stay cleared.
How do I fix the Lower Thermal Sensor SHORTED error on a GE microwave?
Start by disconnecting power and accessing the lower thermistor, then measure its resistance across the red and white leads at Smart Board connector CN09. If the reading is near zero ohms rather than the expected 256K ohms at room temperature, the thermistor needs to be replaced. Also inspect the wiring harness for any chafed, pinched, or burned insulation that could be causing the short before the signal reaches the board. If both the sensor and wiring check out, the Smart Board may need to be evaluated.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass