Goodman Hvac Error Code 1
Ignition failure, open rollout switch, or open auxiliary limit switch detected by the DSI ignition control…
Ignition failure, open rollout switch, or open auxiliary limit switch detected by the DSI ignition control module.
First step from the service manual
Check gas flow, gas pressure, gas valve, flame sensor, flame rollout, and auxiliary limit.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for 1.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What 1 means on a Goodman hvac
Error code 1 on a Goodman furnace indicates that the DSI (Direct Spark Ignition) control module has detected one of three conditions: an ignition failure during a heating cycle, an open rollout switch, or an open auxiliary limit switch. The DSI module monitors the ignition sequence and flame signal continuously. If the burner fails to light within the allotted trial period, or if either the rollout or auxiliary limit switch opens during operation, the module locks out and displays this fault code.
Ignition failure is typically traced to insufficient gas supply, low gas pressure, a faulty gas valve, or a contaminated or failed flame sensor. The flame sensor must detect a microamp signal from the burner flame to confirm ignition. If the sensor is coated with oxidation or debris, it cannot pass enough current to satisfy the control module, causing a lockout. Gas pressure should be verified at the manifold to confirm it falls within the furnace's rated operating range.
An open rollout switch indicates that flames have exited the burner compartment in an abnormal direction, typically due to a blocked heat exchanger, restricted flue, or inducer motor failure. An open auxiliary limit switch signals that temperatures in the heat exchanger or plenum area have exceeded safe operating thresholds, often caused by restricted airflow from a clogged filter, blocked vents, or a failed blower motor. Both rollout and auxiliary limit switches are safety devices and should be carefully inspected before being manually reset.
Source: manufacturer service documentation.
Common causes of 1
- 01
Dirty or failed flame sensor
Wiring / connectionA flame sensor coated with oxidation or carbon deposits cannot pass sufficient microamp current to confirm ignition, causing the DSI module to time out and lock out. Inspect the sensor rod and clean it with fine steel wool or emery cloth.
- 02
Insufficient gas pressure or gas flow
Wiring / connectionLow gas supply pressure or a closed shutoff valve prevents the burners from igniting reliably during the trial period. Verify that the manual gas shutoff is fully open and that manifold pressure matches the furnace rating.
- 03
Faulty or failed gas valve
Part replacementA gas valve that does not open properly or fails electrically will prevent gas from reaching the burners during the ignition sequence. Check for the correct voltage signal at the valve terminals and confirm the valve responds.
- 04
Open rollout switch
Wiring / connectionIf flames have rolled out of the burner compartment due to a blocked flue, cracked heat exchanger, or failed inducer, the rollout switch opens to prevent a fire hazard. The switch must be manually reset after the root cause is identified and corrected.
- 05
Open auxiliary limit switch due to restricted airflow
Wiring / connectionA clogged air filter, blocked return or supply vents, or a failed blower motor can cause excessive heat buildup, tripping the auxiliary limit switch. Check and replace the air filter, clear any vent obstructions, and confirm the blower motor is operating.
Frequently asked questions about 1
What does 1 mean on a Goodman hvac?
Can I fix error code 1 on my Goodman furnace myself?
Is error code 1 on a Goodman furnace dangerous?
Will resetting the furnace clear error code 1?
How much does it cost to repair a Goodman furnace showing error code 1?
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass