Goodman HVAC Error Code 1

Ignition failure, open rollout switch, or open auxiliary limit switch detected by the DSI ignition control module.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 1 error code actually means

Your Goodman furnace tried to light but either could not ignite the burner, or a safety switch detected a dangerous condition and shut things down. This could be a gas supply problem, a dirty sensor, or a sign that something is blocking airflow or causing flames to behave abnormally. The furnace will not run until the underlying problem is found and corrected.

Diagnostic procedure

The full 1 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check gas flow, gas pressure, gas valve, flame sensor, flame rollout, and auxiliary limit.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 1 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 1

Ranked by how often they cause this code
  1. 1Dirty or failed flame sensor
  2. 2Insufficient gas pressure or gas flow
  3. 3Faulty or failed gas valve
  4. 4Open rollout switch
  5. 5Open auxiliary limit switch due to restricted airflow

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 1

What does 1 mean on a Goodman hvac?
Error code 1 on a Goodman furnace means the DSI ignition control module detected either an ignition failure, an open rollout switch, or an open auxiliary limit switch. These conditions all prevent the furnace from completing a safe heating cycle. The code is the module's way of reporting that the burner did not light successfully or that a safety device tripped during operation.
Is error code 1 on a Goodman furnace dangerous?
An open rollout switch is a serious safety condition that means flames have extended outside the burner compartment, which can pose a fire risk. Do not simply reset the rollout switch and restart the furnace without determining why it tripped. An open auxiliary limit switch also signals overheating that should be addressed before continuing operation. Both conditions warrant careful inspection before the furnace is put back into service.
How much does it cost to repair a Goodman furnace showing error code 1?
Repair costs vary widely depending on the cause. Cleaning a flame sensor is a low-cost service call, typically in the range of $75 to $150 including labor. Replacing a gas valve is more involved and can range from $200 to $600 or more depending on parts and labor rates in your area. Diagnosing a blocked heat exchanger or flue issue may also reveal additional repairs needed, so costs can vary significantly.
Can I fix error code 1 on my Goodman furnace myself?
Some causes of error code 1 are DIY-friendly, such as replacing a dirty air filter, cleaning the flame sensor, or checking that the gas shutoff valve is fully open. However, diagnosing a tripped rollout switch, testing gas valve operation, or measuring manifold gas pressure requires proper tools and knowledge of gas appliance safety. If you are not comfortable working with gas components, contact a licensed HVAC technician.
Will resetting the furnace clear error code 1?
Cycling power to the furnace may temporarily clear the lockout and allow the furnace to attempt another ignition sequence, but the error code will return if the underlying cause has not been resolved. Rollout switches must be manually reset at the switch itself after the cause of rollout has been corrected. Addressing the root cause is necessary for the error to clear permanently.