What the 2 Flashes error code actually means

Your furnace detected that a safety sensor called the pressure switch was triggered before the system even tried to start the fan that pulls air through the furnace. This usually means the pressure switch is stuck, has a blocked hose, or has a wiring problem. The furnace shut itself down as a precaution to keep your home safe.

Diagnostic procedure

The full 2 Flashes procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check pressure switch and hose connections for proper operation.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 2 Flashes procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 2 Flashes

Ranked by how often they cause this code
  1. 1Stuck or faulty pressure switch
  2. 2Blocked, kinked, or cracked pressure switch hose
  3. 3Wiring short in the pressure switch circuit
  4. 4Moisture or condensate in the pressure switch or tubing
  5. 5Faulty control board 103085

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 2 Flashes

What does 2 Flashes mean on a Lennox furnace?
The 2 Flashes code on a Lennox furnace with control board 103085 means the pressure switch is detected in a closed state before the combustion air inducer motor has been turned on. This is a safety fault because the pressure switch should only close after the inducer builds up airflow. The furnace locks out to prevent unsafe operation until the fault is resolved.
Is the 2 Flashes error on a Lennox furnace a safety concern?
Yes, this fault code exists specifically to protect your home. The furnace shuts down because the pressure switch, which monitors safe airflow through the venting system, is signaling incorrectly. Running the furnace without resolving this fault could mask a real venting or airflow problem, so the issue should be diagnosed and corrected before relying on the system for heat.
How much does it cost to repair a Lennox furnace showing 2 Flashes?
Repair costs depend on the root cause. If only hose cleaning or repositioning is needed, costs may be limited to a service call fee, typically in the range of $75 to $150. A replacement pressure switch generally runs between $20 and $80 for the part, plus labor. If the control board 103085 is faulty, parts and labor combined can range from $300 to $600 or more depending on your region and service provider.
How do I fix the 2 Flashes error on my Lennox furnace?
Start by inspecting the pressure switch hose for kinks, cracks, moisture, or blockages and clear or replace the hose if needed. Next, test the pressure switch itself for continuity with the inducer off. If the switch contacts are closed when they should be open, the switch needs to be replaced. If the hose and switch both check out, inspect the wiring between the switch and the control board for any shorts or damage.
Will resetting my Lennox furnace clear the 2 Flashes error?
Resetting the furnace by cycling the power may temporarily clear the fault and allow a restart attempt, but the error will return if the underlying problem is not fixed. If the pressure switch is stuck closed or the hose is obstructed, the fault will reappear almost immediately during the next startup sequence. A proper diagnosis and repair of the root cause is necessary for a lasting fix.