mypros+
Error code reference

LG Heat Pump Error Code 45

Outdoor unit pipe sensor (left) open or short circuit.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 45 error code actually means

Your LG heat pump has detected a problem with a temperature sensor located on the outdoor unit's refrigerant piping. This sensor has either lost its electrical connection or developed an internal fault, so the system can't read pipe temperatures properly and has shut down as a safety measure. A technician will need to inspect the sensor wiring and test the sensor itself to determine whether it needs to be reconnected or replaced.

Diagnostic procedure

The full 45 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Confirm state of sensor connection to PCB; if normal, measure resistance/voltage of sensor.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 45 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 45

Ranked by how often they cause this code
  1. 1Loose or disconnected sensor connector at PCB
  2. 2Failed thermistor (open circuit)
  3. 3Damaged sensor wiring or harness
  4. 4Corroded or contaminated connector terminals
  5. 5Faulty outdoor unit PCB

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 45

What does 45 mean on a LG heat_pump?
Error code 45 on an LG heat pump indicates that the outdoor unit pipe sensor on the left side has been detected with an open or short circuit fault. The control board cannot read a valid resistance signal from this thermistor, so it shuts down operation to protect the system. The fault points to either a wiring or connector issue, a failed sensor, or in rare cases, a faulty PCB input circuit.
Will resetting my LG heat pump clear error code 45?
A power reset may temporarily clear the error display, but the code will return immediately if the underlying sensor fault is still present. Because the PCB actively monitors the sensor signal during operation, a failed or disconnected thermistor will trigger the fault again as soon as the unit powers back up. The sensor connection and sensor condition must be physically corrected before the error will stay cleared.
How much does it cost to repair error code 45 on an LG heat pump?
If the fix is simply reseating a loose connector, you may incur only a diagnostic service call fee, typically in the range of $75 to $150 depending on your area. Replacing the outdoor pipe thermistor sensor is a relatively low-cost repair, with parts generally ranging from $20 to $60 and total repair costs including labor often falling between $100 and $250. If the outdoor unit PCB is the root cause, board replacement is significantly more expensive, often ranging from $300 to $600 or more with labor.
Can I fix error code 45 on my LG heat pump myself?
A knowledgeable DIYer can inspect the sensor connector at the outdoor PCB for loose or corroded pins and reseat it if needed, which sometimes clears the fault. However, testing thermistor resistance requires a multimeter and familiarity with reading sensor resistance curves, and working inside an outdoor unit involves refrigerant-side components that should be handled carefully. If the sensor or PCB needs replacement, a qualified HVAC technician is recommended.
Is it safe to keep running my LG heat pump with error code 45 active?
In most cases the heat pump will not operate normally while error code 45 is active, as the system shuts down to protect the compressor and refrigerant circuit from running without accurate pipe temperature data. Attempting to bypass or ignore the fault is not recommended, since the pipe sensor data is used to manage defrost cycles and refrigerant flow control. Continued operation without a functioning sensor risks compressor damage.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass