mypros+
Error code reference

LG Heat Pump Error Code CH02

Problem in Refrigerant (Inlet side) sensor.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the CH02 error code actually means

Your LG heat pump has detected a problem with a small temperature sensor that monitors refrigerant flowing through the system. The unit's control board either cannot read the sensor's signal or is receiving a reading that falls outside normal limits. Until this is resolved, the heat pump may not heat or cool your home properly.

Diagnostic procedure

The full CH02 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check if sensor is properly connected to PCB; measure resistance (5k ohm at 25°C unplugged) or voltage (2.5Vdc at 25°C plugged).
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock CH02 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of CH02

Ranked by how often they cause this code
  1. 1Loose or disconnected sensor connector
  2. 2Failed refrigerant inlet sensor
  3. 3Corroded or damaged wiring connector
  4. 4Damaged sensor lead wire
  5. 5Faulty PCB

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about CH02

What does CH02 mean on a LG heat_pump?
CH02 indicates a problem with the refrigerant inlet side temperature sensor. The control board is receiving a signal from this sensor that is outside of normal operating parameters. This sensor should measure approximately 5k ohms resistance at 25 degrees Celsius when unplugged, or approximately 2.5Vdc when connected and powered. The system flags CH02 when those values are not met.
Is it safe to keep running my heat pump with a CH02 error?
Continued operation with a CH02 error is not recommended. The refrigerant inlet sensor provides critical data the control board uses to protect the compressor and manage refrigerant flow. Running the system without reliable sensor input can lead to improper operation, reduced efficiency, or compressor damage over time.
How much does it cost to repair a CH02 error on an LG heat pump?
Repair costs vary depending on the root cause. A replacement refrigerant inlet temperature sensor typically costs between 15 and 60 dollars for the part alone. If a service technician is needed for diagnosis and replacement, total costs including labor can range from 100 to 350 dollars or more. PCB replacement, if required, will increase costs significantly.
Can I fix the CH02 error myself?
A knowledgeable DIYer can perform the initial checks, including inspecting the sensor connector for proper seating and measuring resistance at the sensor with a multimeter. If the connector is secure and the resistance reads near 5k ohms at 25 degrees Celsius, the wiring or PCB may be at fault. Sensor replacement is relatively straightforward, but any work involving refrigerant circuits or PCB replacement should be handled by a qualified technician.
Will resetting the heat pump clear the CH02 error?
A reset may temporarily clear the code, but if the underlying sensor, wiring, or connector problem is still present, CH02 will return. Resetting without diagnosis and repair is not a lasting solution and may delay finding the actual fault.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass