LG Heat Pump Error Code CH21

DC Peak (IPM Fault)

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the CH21 error code actually means

Your LG heat pump has detected a dangerous spike of electrical current inside the part that controls the compressor speed, and it shut down to prevent a more serious breakdown. This can be caused by a loose wire, a problem with the compressor itself, or an issue with the incoming power supply. A technician will need to check the electrical components before the unit can safely run again.

Diagnostic procedure

The full CH21 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check U,V,W wire connections; check input power voltage (1Ph: 230V±10%, 3Ph: 400V±10%); check compressor resistance and insulation; check DC link capacitor.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock CH21 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of CH21

Ranked by how often they cause this code
  1. 1Loose or faulty U, V, W phase wiring
  2. 2Compressor winding short or insulation failure
  3. 3Input supply voltage out of tolerance
  4. 4Failed or degraded DC link capacitor
  5. 5Damaged or failed IPM module

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about CH21

What does CH21 mean on a LG heat_pump?
CH21 indicates a DC Peak fault caused by an instantaneous overcurrent detected in the U, V, or W output phase of the inverter's IPM (Intelligent Power Module). The unit shuts down immediately to protect the IPM from damage. The fault can stem from wiring problems, compressor faults, supply voltage issues, or a failing DC link capacitor. A qualified technician should diagnose the root cause before restarting the system.
Is it safe to keep running my heat pump with a CH21 error?
No. The CH21 fault causes the unit to shut down specifically because continuing to operate with an overcurrent condition risks destroying the IPM and potentially damaging connected compressor windings. Operating the unit in a fault state could escalate a relatively inexpensive repair into a full compressor or inverter board replacement. Leave the unit off until the underlying cause is identified and corrected.
Will resetting the unit clear a CH21 error?
A power reset may temporarily clear the fault display, but if the underlying problem persists, the CH21 code will return, often immediately upon the next compressor startup attempt. Resetting without diagnosis does not fix the fault and can cause additional stress on the IPM each time the compressor tries to start against a fault condition. A proper repair requires identifying and correcting the root cause, whether that is a wiring issue, voltage problem, compressor fault, or a failed component.
Can I fix a CH21 error myself?
Some preliminary checks, such as visually inspecting phase wire connections at the compressor for looseness or corrosion, can be performed by a knowledgeable DIYer. However, properly diagnosing this fault requires measuring live supply voltage, testing compressor winding resistance and insulation, and evaluating the DC link capacitor and IPM, all of which involve dangerous voltages. Most of the required diagnostic and repair work should be performed by a licensed HVAC or refrigeration technician.
How much does it cost to repair a CH21 fault on an LG heat pump?
Repair costs vary widely depending on the root cause. If the fix is simply reseating a loose wire connection, the cost may only be a service call fee, typically in the range of $80 to $200. Replacing a DC link capacitor or IPM module can run $300 to $700 or more including parts and labor. A failed compressor is the most expensive outcome, with replacement costs ranging from $1,000 to $2,500 or higher depending on the unit size and refrigerant type.