LG Heat Pump Error Code CH22

Max CT (over current detected by current transformer).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the CH22 error code actually means

Your LG heat pump detected that the compressor was drawing too much electrical current and shut itself down to prevent serious damage. This can happen because of an electrical wiring problem, a refrigerant issue, or a blockage in the outdoor unit. A technician needs to inspect the system before it is safe to restart.

Diagnostic procedure

The full CH22 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check U,V,W wire connections; check input power voltage; check compressor resistance and insulation; check for overload conditions (overcharged refrigerant, blocked condenser, locked fan).
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock CH22 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of CH22

Ranked by how often they cause this code
  1. 1Loose or miswired U, V, W compressor connections
  2. 2Low or unbalanced input power voltage
  3. 3Overcharged refrigerant system
  4. 4Blocked or dirty condenser coil or locked fan motor
  5. 5Degraded compressor winding insulation or internal short

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about CH22

What does CH22 mean on a LG heat_pump?
CH22 indicates that the current transformer monitoring the compressor circuit detected an overcurrent condition, meaning the compressor was drawing more electrical current than the maximum safe limit. The system shuts down automatically to protect the compressor and related electrical components from damage. The fault can originate from wiring issues, supply voltage problems, refrigerant charge problems, or mechanical blockages in the outdoor unit.
Is it safe to keep running my LG heat pump with a CH22 error?
No. The unit has already shut down as a protective measure, and attempting to force it to run while the underlying cause is unresolved risks permanent compressor failure or an electrical hazard. Leave the system off and have it inspected before resuming operation.
How much does it cost to repair a CH22 error on an LG heat pump?
Repair cost varies widely depending on the cause. A simple wiring correction or condenser cleaning may cost between $75 and $200 for a service call. Refrigerant recovery and recharge can add $150 to $400 or more depending on the refrigerant type and quantity involved. Compressor replacement, which is required if internal winding damage is confirmed, typically ranges from $800 to $2,500 or higher depending on the unit size and labor rates in your area.
Can I fix CH22 on my LG heat pump myself?
Some preliminary checks, such as inspecting the outdoor unit for debris blocking the condenser coil or fan, can be done safely by a homeowner. However, diagnosing wiring faults, measuring compressor insulation resistance, and evaluating refrigerant charge require specialized tools and training. Because the fault involves high-voltage compressor circuits, most of the repair work should be performed by a licensed HVAC technician.
Will resetting the unit clear the CH22 fault?
A power reset may temporarily clear the fault code, but the error will return quickly if the root cause has not been addressed. Repeatedly resetting the unit without fixing the underlying problem can accelerate damage to the compressor. A reset should only be performed after the cause of the overcurrent condition has been identified and corrected.