What the CH23 error code actually means

Your LG heat pump is detecting that an internal electrical voltage level has dropped too low to run the compressor safely, so it shut itself off. This is usually related to a power supply problem, either from your home's electrical supply or from a loose or worn connection inside the unit. A technician will need to measure voltage levels and inspect the wiring to find the exact cause.

Diagnostic procedure

The full CH23 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check power source; check wire connections and components; verify DC link voltage per table.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock CH23 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of CH23

Ranked by how often they cause this code
  1. 1Low incoming AC line voltage
  2. 2Loose or corroded wire connections
  3. 3Failed or degraded DC link capacitors
  4. 4Faulty rectifier section
  5. 5Undersized or overloaded circuit

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about CH23

What does CH23 mean on a LG heat_pump?
CH23 indicates that the DC link voltage inside the heat pump's inverter section has fallen below the minimum required level. For single-phase units, this threshold is 140Vdc, and for three-phase units it is 250Vdc. The system shuts down automatically to protect the compressor from running under inadequate voltage conditions. The fault points to either a power supply issue or a failing internal electrical component.
Is it safe to keep using my heat pump when CH23 appears?
No. CH23 causes the unit to shut down specifically to prevent compressor damage from low voltage operation. Attempting to bypass the fault or repeatedly resetting and running the unit without identifying the cause can damage the compressor or inverter board. The unit should remain off until the underlying cause is diagnosed and corrected.
How much does it cost to repair a CH23 fault on an LG heat pump?
Repair costs vary widely depending on the cause. If the fix involves tightening connections or correcting a circuit issue, costs may be limited to a service call fee, typically in the range of $75 to $200. If the DC link capacitors or inverter board need replacement, parts and labor combined can range from $300 to $900 or more depending on the unit size and part availability. Getting a diagnostic visit first will clarify exactly what parts are needed.
Can I fix CH23 myself, or do I need a technician?
Basic checks such as inspecting the circuit breaker, verifying the disconnect is fully closed, and looking for obviously loose wiring at accessible terminals can be done carefully by a knowledgeable homeowner. However, measuring DC link voltage and testing internal components like capacitors and rectifiers involves working with high-voltage DC circuits, which is hazardous without proper training and equipment. A qualified HVAC technician should perform the full diagnostic procedure.
Will resetting the unit clear the CH23 error?
A power reset may temporarily clear the fault code and allow the unit to restart, but if the underlying cause has not been corrected, CH23 will return, often immediately or at the next compressor start attempt. Persistent or recurring CH23 faults after a reset indicate an active electrical problem that requires diagnosis rather than simply clearing the code.