LG Heat Pump Error Code CH24

High Pressure / Low Pressure switch activated.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the CH24 error code actually means

Your LG heat pump has detected that the refrigerant pressure inside the system is either too high or too low, which caused a built-in safety switch to shut the unit down. This usually means there is a refrigerant leak, a blocked airflow path, or a valve that is not fully open. The system will not restart safely until the underlying pressure problem is diagnosed and corrected.

Diagnostic procedure

The full CH24 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check CN_PRESS connector connection; check service valve is open; check for refrigerant leakage; check suction and discharge pipe pressures.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock CH24 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of CH24

Ranked by how often they cause this code
  1. 1Refrigerant Leak
  2. 2Loose or Faulty CN_PRESS Connector
  3. 3Closed or Partially Closed Service Valve
  4. 4Blocked or Restricted Airflow
  5. 5Refrigerant Overcharge

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about CH24

What does CH24 mean on a LG heat_pump?
CH24 means the unit's high pressure switch or low pressure switch has been activated, indicating the refrigerant circuit is operating outside of safe pressure limits. The control board shuts the system down to protect the compressor from damage. The fault can originate on either the high side or the low side of the refrigerant circuit, so pressure measurements are needed to determine which switch tripped. Common causes include refrigerant leaks, a closed service valve, or blocked airflow.
Is it safe to keep running my LG heat pump with a CH24 code?
No, CH24 should not be ignored. The pressure switches are safety devices designed to prevent compressor failure, and continued operation with abnormal refrigerant pressures can cause permanent damage to the compressor. The unit should remain off until the fault is diagnosed and the underlying pressure issue is resolved.
How much does it cost to repair a CH24 error on an LG heat pump?
Repair costs vary widely depending on the root cause. A service call to inspect the connector and service valves may range from $75 to $150. If a refrigerant leak is found, the cost to locate the leak, make repairs, and recharge the system can range from $250 to $600 or more depending on the refrigerant type and amount needed. Compressor replacement, if damage has already occurred, is significantly more expensive.
Can I fix a CH24 error on my LG heat pump myself?
Some causes of CH24, such as a loose CN_PRESS connector or a partially closed service valve, can be addressed without specialized tools. However, diagnosing refrigerant pressure requires a manifold gauge set, and any refrigerant handling or recharge work must be performed by an EPA-certified technician. Attempting to add refrigerant without finding and repairing a leak will only result in the fault recurring.
Will resetting my LG heat pump clear the CH24 error?
Resetting the unit may temporarily clear the CH24 code and allow the system to restart, but the fault will return if the underlying pressure problem has not been corrected. A reset is useful for confirming whether the fault was caused by a transient condition, but it is not a repair. If the code returns after a reset, a full pressure and refrigerant circuit inspection is required.