mypros+
Error code reference

LG Heat Pump Error Code CH29

High current at compressor phases (inverter compressor input current over 30A).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the CH29 error code actually means

Your LG heat pump has detected that the compressor is drawing too much electrical current, which triggered a safety shutdown to prevent damage. This can happen because of a refrigerant problem, a failing compressor, or an electrical issue with the power supply or wiring. A technician will need to inspect the refrigerant circuit, measure the compressor's electrical values, and check the power supply before the system can be safely restarted.

Diagnostic procedure

The full CH29 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check installation condition (pipe clogging, covering, EEV defect, refrigerant overcharge); check compressor resistance between phases (0.188±7% ohm) and insulation (over 50M ohm); check wire connections; check input voltage (220V±15%).
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock CH29 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of CH29

Ranked by how often they cause this code
  1. 1Refrigerant overcharge or restriction
  2. 2Defective electronic expansion valve (EEV)
  3. 3Compressor winding degradation
  4. 4Incorrect or unstable input voltage
  5. 5Loose or corroded compressor wiring connections

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about CH29

What does CH29 mean on a LG heat_pump?
CH29 indicates that the inverter compressor input current has exceeded 30 amperes across its phases, triggering a protective shutdown. The system monitors current on all compressor phases and shuts down when it detects this overcurrent condition. The fault can originate from refrigerant system problems, a failing compressor, voltage issues, or faulty wiring connections. A complete diagnosis should cover all of these areas before any parts are replaced.
Is it safe to keep running my heat pump with a CH29 code showing?
No, you should not attempt to keep the system running with CH29 active. The fault represents a real overcurrent condition that can damage the compressor, inverter drive board, or wiring if the system is forced to restart repeatedly. Leave the unit off until the root cause has been identified and corrected.
How much does it cost to repair a CH29 error on an LG heat pump?
Repair costs vary widely depending on the root cause. A simple fix such as clearing a refrigerant restriction or tightening connections may cost between $100 and $250 for a service call. Refrigerant adjustment or an EEV replacement typically runs between $200 and $600. If the compressor itself has failed, replacement costs including labor can range from $800 to $2,000 or more depending on the unit size and local labor rates.
Can I fix a CH29 error myself?
Some basic checks are within reach of a knowledgeable DIYer, such as verifying that nothing is blocking or covering the outdoor unit and confirming that supply voltage at the disconnect is near 220V. However, measuring compressor winding resistance and insulation values, checking refrigerant charge, and testing the EEV require specialized tools and, in most areas, EPA certification to handle refrigerant. It is best to have a licensed HVAC technician complete the full diagnosis.
Will resetting the unit clear the CH29 error?
A power reset may temporarily clear the fault display, but the error will return as soon as the underlying condition causes current to exceed 30 amperes again. Resetting without addressing the root cause risks further damage to the compressor or inverter components. The fault should be fully diagnosed and repaired before the system is returned to normal operation.

78,000+ service manuals · 160,000+ error codes · 55+ brands