LG Heat Pump Error Code CH62

Temperature at heatsink is too high (85°C).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the CH62 error code actually means

Your LG heat pump detected that a key electronic component inside the outdoor unit got too hot and shut itself down to prevent damage. This is usually caused by something blocking airflow, a refrigerant problem, or a failing fan. A technician will need to find out why it overheated before it is safe to run the system again.

Diagnostic procedure

The full CH62 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check for overload conditions (refrigerant leakage, blocked condenser, locked outdoor fan); check heat sink sensor resistance (10k ohm at 25°C) and voltage (2.5Vdc at 25°C).
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock CH62 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of CH62

Ranked by how often they cause this code
  1. 1Blocked or dirty condenser coil
  2. 2Locked or failed outdoor fan motor
  3. 3Refrigerant leakage or low charge
  4. 4Failed or drifted heat sink NTC thermistor
  5. 5Poor ventilation around the outdoor unit

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about CH62

What does CH62 mean on a LG heat_pump?
CH62 indicates that the heat sink temperature on the outdoor inverter module reached the protection threshold of 85°C and the unit shut down to prevent damage. The heat sink is attached to the power electronics that control compressor speed. The fault can be caused by airflow restrictions, a failed fan, low refrigerant, or a faulty temperature sensor. A technician should inspect the outdoor unit before restarting the system.
Is it safe to keep running my heat pump when CH62 is displayed?
No. The unit has already shut down automatically to protect the inverter electronics from heat damage. Attempting to force the system to run while the underlying cause is still present risks permanent damage to the IPM or inverter board. The system should remain off until the cause is diagnosed and corrected.
How much does it cost to repair a CH62 error on an LG heat pump?
Repair costs vary widely depending on the cause. Cleaning the condenser coil is a relatively low-cost service call, while replacing a fan motor typically runs in the range of $150 to $450 including parts and labor. If refrigerant needs to be recovered and recharged, costs generally fall between $200 and $600 depending on refrigerant type and the amount needed. Replacing the heat sink NTC sensor is usually on the lower end of repair costs, often $75 to $200.
Can I fix CH62 myself, or do I need a technician?
Some causes, like cleaning a blocked condenser coil or clearing debris from around the outdoor unit, can be addressed without professional help. However, diagnosing a locked fan motor, checking refrigerant charge, or testing the heat sink sensor voltage and resistance requires proper tools and training. Refrigerant work in particular is regulated and must be performed by a certified technician.
Will resetting the unit clear the CH62 error?
A power reset may temporarily clear the fault and allow the unit to restart, but if the root cause is not addressed, the heat sink will overheat again and CH62 will return. Repeated cycling through this fault without repair can eventually cause permanent damage to the inverter components. A reset should only be performed after the underlying issue has been identified and corrected.