LG Heat Pump Error Code CH73

AC input instant over current error

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the CH73 error code actually means

Your LG heat pump detected a sudden surge of electrical current in its main power circuit that was large enough to potentially damage internal components, so it shut itself down as a safety measure. This can happen because of a refrigerant problem, a power supply issue, or a fault inside the unit's control electronics. A qualified technician needs to inspect the system before it is restarted.

Diagnostic procedure

The full CH73 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check installation condition (pipe clogging, covering, EEV defect, refrigerant overcharge); check input voltage (220V±10%); check AC input and compressor wire connections; check inverter PCB assembly IPM.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock CH73 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of CH73

Ranked by how often they cause this code
  1. 1Refrigerant overcharge or circuit restriction
  2. 2Defective electronic expansion valve (EEV)
  3. 3AC input voltage out of range
  4. 4Loose or damaged AC input and compressor wiring connections
  5. 5Failed inverter PCB or degraded IPM

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about CH73

What does CH73 mean on a LG heat_pump?
CH73 indicates an AC input instantaneous overcurrent fault. The inverter PCB detected input current exceeding 48 amperes peak for at least 2 milliseconds, which is above the safe operating limit for the unit's Intelligent Power Module. The system shuts down automatically to prevent component damage. The fault can stem from refrigerant circuit issues, incorrect supply voltage, wiring problems, or a failing inverter PCB.
Is it safe to keep using my heat pump while CH73 is displayed?
No, continued operation with a CH73 fault is not safe for the equipment. The overcurrent condition that triggers this code can permanently damage the Intelligent Power Module inside the inverter PCB and may also harm the compressor. The unit should remain off until a qualified technician has inspected the refrigerant circuit, electrical supply, wiring, and inverter board.
What should a technician check first when diagnosing CH73?
The first steps are to inspect the refrigerant circuit for pipe restrictions, blocked coils, EEV operation, and refrigerant overcharge, then verify that AC supply voltage at the unit is within 220V plus or minus 10% under load. After those are confirmed acceptable, the technician should inspect all AC input wiring and compressor wiring connections for looseness or damage. If all external conditions are normal, the inverter PCB assembly and its IPM should be evaluated.
Can I reset the CH73 error myself to get the unit running again?
Power cycling the unit may temporarily clear the CH73 code, but the fault will almost certainly return if the underlying cause is not corrected. Running the system repeatedly with an active overcurrent condition risks damaging the inverter PCB and compressor. It is strongly recommended to diagnose and correct the root cause before attempting to resume normal operation.
How much does it typically cost to repair a CH73 error on an LG heat pump?
Repair cost depends entirely on the root cause. If the issue is a loose wire connection or an out-of-range refrigerant charge, costs are relatively low, typically in the range of $100 to $300 for a service call and labor. If an EEV replacement is needed, expect $200 to $500 in parts and labor. An inverter PCB replacement is the most expensive scenario, often ranging from $500 to $1,200 or more depending on the model and labor rates in your area.