LG Heat Pump Error Code Cx

Electronic expansion valve open error for xth indoor unit

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the Cx error code actually means

Your LG heat pump has detected that one of the indoor units is getting unusually cold even though it has been turned off, which suggests refrigerant is still flowing into it when it should not be. This is typically caused by a small valve that controls refrigerant flow not closing properly. A technician will need to check the wiring and the valve component to restore normal operation.

Diagnostic procedure

The full Cx procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check EEV wire connection to indoor unit PCB; check EEV coil insertion; press reset key (K3) to recheck.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock Cx procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of Cx

Ranked by how often they cause this code
  1. 1Loose or disconnected EEV coil
  2. 2EEV wiring harness fault at indoor PCB
  3. 3Failed EEV coil
  4. 4Mechanically stuck or failed EEV body
  5. 5Indoor unit PCB control output failure

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about Cx

What does Cx mean on a LG heat_pump?
The Cx code means the electronic expansion valve for the xth indoor unit has an open error. The system detects that a stopped indoor unit has inlet or outlet pipe temperatures below 0°C for 2.5 minutes during cooling, indicating refrigerant is flowing through the unit when it should not be. The "x" in the code corresponds to which indoor unit is affected in a multi-zone setup.
Is it safe to keep running my LG heat pump while the Cx error is active?
Continuing to operate the system with an active Cx error is not recommended. An open EEV in a stopped indoor unit can cause refrigerant flooding in that unit, which may lead to liquid refrigerant returning to the compressor and causing compressor damage over time. It is best to address the fault before resuming normal operation.
Will resetting the system clear the Cx error code?
Pressing the reset key (K3) is part of the recommended diagnostic process and will prompt the system to recheck the EEV condition. If the underlying cause was a temporarily loose connection that has since been reseated, the reset may clear the fault. However, if the EEV coil, wiring, or valve body has a genuine fault, the error will return after the system attempts to verify valve operation during cooling mode.
Can I fix the Cx error myself or do I need a technician?
Some basic checks are accessible to a knowledgeable DIYer, such as verifying the EEV coil is fully seated on the valve body and checking that the wiring harness is securely connected to the indoor PCB. Pressing the reset key (K3) after confirming connections can clear the fault if a loose connection was the cause. However, if the EEV coil, valve body, or PCB requires replacement, a licensed HVAC technician with refrigerant handling certification should perform the repair.
How much does it cost to repair the Cx error on an LG heat pump?
Repair costs vary depending on the root cause. If the issue is simply a loose EEV coil or wiring connection, a service call diagnostic fee may be the primary cost, typically in the range of $75 to $150. If the EEV coil requires replacement, parts and labor combined generally range from $150 to $400. A failed valve body or PCB replacement can push total costs higher, often in the $300 to $700 range or more depending on the unit.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass