mypros+
Error code reference

LG Heat Pump Error Code E105

Indoor unit EVAP IN sensor breakaway.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E105 error code actually means

Your LG heat pump is showing E105 because a small temperature sensor inside the indoor unit has slipped off the pipe it is supposed to be touching. The system noticed the sensor readings no longer made sense and stopped normal operation to protect itself. This is typically a straightforward fix involving reattaching the sensor to its pipe.

Diagnostic procedure

The full E105 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check if indoor unit EVAP IN sensor is separated from pipe and reassemble.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E105 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E105

Ranked by how often they cause this code
  1. 1Sensor clip or bracket failure
  2. 2Sensor dislodged during maintenance
  3. 3Vibration-induced sensor migration
  4. 4Deteriorated foam insulation sleeve
  5. 5Damaged sensor or sensor lead wire

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E105

What does E105 mean on a LG heat pump?
E105 means the indoor unit's evaporator inlet (EVAP IN) temperature sensor has physically separated from the pipe it monitors. This thermistor is clipped directly to the refrigerant pipe at the inlet of the evaporator coil. When it loses contact, the control board detects abnormal readings and triggers E105 to prevent the system from operating on inaccurate data.
Is it safe to run my LG heat pump while E105 is active?
It is not advisable to continue running the unit with E105 active. The system is designed to limit or halt operation when this fault is present because the control board is receiving inaccurate evaporator temperature data. Operating under these conditions could lead to coil icing, inefficient performance, or compressor stress over time.
How much does it cost to repair an E105 error on an LG heat pump?
If the fix is simply reattaching the sensor, a service call cost will typically range from around $75 to $150 depending on your location and the technician's rates. If the sensor itself needs to be replaced, parts and labor together could run from $100 to $250 or more. Doing the reattachment yourself, if you are comfortable accessing the indoor unit, costs nothing beyond your time.
Can I fix E105 myself without calling a technician?
In many cases, yes. The repair involves opening the indoor unit, locating the EVAP IN sensor on the evaporator inlet pipe, and firmly reattaching it so it makes good contact with the pipe surface. No refrigerant work is involved. If the sensor clip is broken or the sensor itself is damaged, a replacement part may be needed, at which point a technician familiar with LG systems is recommended.
Will resetting the heat pump clear the E105 code?
A simple power reset may temporarily clear the E105 code, but it will return if the sensor is still separated from the pipe. The only reliable way to clear the fault permanently is to physically reseat the sensor against the evaporator inlet pipe and secure it properly before resetting the unit.