mypros+
Error code reference

LG Heat Pump Error Code E106

Indoor unit EVAP OUT sensor breakaway.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E106 error code actually means

Your LG heat pump is showing E106 because a small temperature sensor inside the indoor unit has fallen off or slipped away from the pipe it is supposed to be touching. The system cannot get an accurate reading and has shut down to protect itself. In many cases, this can be fixed by reattaching the sensor to the pipe without needing any new parts.

Diagnostic procedure

The full E106 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check if indoor unit EVAP OUT sensor is separated from pipe and reassemble.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E106 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E106

Ranked by how often they cause this code
  1. 1Sensor physically dislodged from pipe
  2. 2Sensor clip broken or worn out
  3. 3Sensor dislodged during maintenance
  4. 4Damaged sensor wiring
  5. 5Faulty EVAP OUT thermistor

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E106

What does E106 mean on a LG heat_pump?
E106 on an LG heat pump means the indoor unit evaporator outlet (EVAP OUT) temperature sensor has separated from the refrigerant pipe it is supposed to be monitoring. The control board detected that the sensor is no longer reading a valid pipe temperature and shut the system down. This is primarily a mechanical mounting issue rather than an electrical or refrigerant fault.
Is it safe to keep running the heat pump while E106 is active?
No. The system is designed to stop operating when E106 is triggered because the control board cannot accurately monitor evaporator outlet temperature. Running the system without this data could lead to compressor damage or improper refrigerant flow. The fault should be addressed before resuming normal operation.
How much does it cost to repair an E106 error on an LG heat pump?
If only sensor repositioning is needed, a service call to diagnose and reattach the sensor typically costs in the range of $75 to $150 depending on your location and the technician's rates. If the EVAP OUT thermistor sensor needs to be replaced, parts and labor combined generally fall in the range of $100 to $250. Costs vary based on local labor rates and parts availability.
Can I fix E106 myself, or do I need a technician?
If the sensor has simply slipped off the pipe, a knowledgeable homeowner or DIYer comfortable opening the indoor unit can reattach it and secure it with insulation tape. However, if the sensor wiring is damaged or the thermistor itself has failed, a qualified HVAC technician should handle the repair to avoid further damage or an incorrect diagnosis.
Will resetting the unit clear the E106 error?
A simple reset will not permanently clear E106 if the sensor is still separated from the pipe. The fault will return as soon as the system runs its startup checks and reads an invalid temperature. The sensor must be physically repositioned and secured against the evaporator outlet pipe before a reset will result in normal operation.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass