LG Heat Pump Error Code E161

The 1st MCU SOL V/V cooling/heating opening at the same time.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E161 error code actually means

Your LG heat pump has detected a conflict where the valve that switches the system between heating and cooling modes is being told to open for both functions at the same time, which is not supposed to happen. This is an internal control system error that the unit cannot resolve on its own. A technician will need to inspect the wiring and control board to find the source of the conflicting signals.

Diagnostic procedure

The full E161 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E161 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E161

Ranked by how often they cause this code
  1. 1MCU control board fault
  2. 2Wiring short or crossover in solenoid valve circuit
  3. 3Faulty solenoid valve coil
  4. 4Loose or corroded connector pins
  5. 5Firmware or MCU logic error

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E161

What does E161 mean on a LG heat_pump?
E161 indicates that the first MCU has detected the solenoid valve for cooling and heating in the open position at the same time. This is a refrigerant circuit control fault where conflicting commands are being sent or read by the main control unit. The system flags this error to prevent damage from operating the refrigerant circuit in an undefined state. A technician needs to diagnose whether the fault originates in the MCU board, the wiring harness, or the solenoid valve itself.
Is it safe to keep running my LG heat pump when E161 is displayed?
It is not recommended to continue operating the heat pump while E161 is active. The error indicates a conflict in the refrigerant circuit switching logic, and running the system in this state could cause compressor stress or refrigerant circuit issues. The unit should be shut down and inspected before restarting.
How much does it cost to repair an E161 error on an LG heat pump?
Repair costs depend on the root cause identified during diagnosis. Wiring repairs or connector replacements are typically on the lower end of the cost range. Solenoid valve coil replacement generally falls in a mid-range cost. MCU control board replacement is usually the most expensive repair, with parts and labor potentially ranging from several hundred to over a thousand dollars depending on the model and local labor rates.
Can I fix E161 on my LG heat pump myself?
Basic checks like inspecting the wiring harness for visible damage, pinched wires, or loose connectors can be done by a knowledgeable DIYer. However, testing MCU output signals and diagnosing the solenoid valve coil requires a multimeter and familiarity with control board circuits. Replacing the MCU or solenoid valve involves refrigerant system work and high-voltage components, which should be handled by a licensed technician.
Will resetting my LG heat pump clear the E161 error?
A full power reset by turning off the unit at the circuit breaker for several minutes may temporarily clear the error if the fault was caused by a transient MCU logic state. However, if the underlying cause is a wiring short, faulty solenoid valve coil, or damaged MCU board, the error will return after the system restarts. Persistent recurrence means the root hardware fault must be repaired.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass