What the E262 error code actually means

Your LG heat pump has detected that two temperature sensors near the compressor are reading very different temperatures from each other, which suggests one sensor may have fallen off or come loose from where it should be attached. The system shuts down or alerts to prevent damage to the compressor, which could be harmed if it runs without accurate temperature monitoring. A technician will need to inspect and reseat the sensor to resolve this.

Diagnostic procedure

The full E262 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check if corresponding compressor sensor is separated; reassemble.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E262 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E262

Ranked by how often they cause this code
  1. 1Discharge sensor physically separated from mounting point
  2. 2Loose or corroded sensor wiring connection
  3. 3Failed digital discharge temperature sensor
  4. 4Failed fixed discharge temperature sensor
  5. 5Control board input fault

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E262

What does E262 mean on a LG heat_pump?
E262 indicates a discharge temperature sensor breakaway condition on compressor 1. The system has detected a difference greater than 40 degrees Celsius between the digital discharge temperature sensor reading and the fixed discharge temperature sensor reading. This typically means one of the sensors has physically separated from its mounting point on the discharge line, causing it to measure ambient air rather than actual compressor discharge temperature.
Is it safe to keep running my LG heat pump with an E262 error?
It is not recommended to continue operating the unit with E262 active. The error exists specifically to protect the compressor from running without reliable discharge temperature monitoring. Operating without accurate discharge temperature data could allow the compressor to run under dangerously high temperatures, potentially causing compressor damage or premature failure.
How much does it cost to repair an E262 error on an LG heat pump?
If the repair only requires reseating a physically separated sensor, the cost could be limited to a service call fee, typically in the range of $75 to $150 depending on your location. If a discharge temperature sensor needs replacement, parts and labor combined generally range from $150 to $350. If the fault has caused compressor damage due to delayed repair, costs can be significantly higher.
How do I fix error code E262 on my LG heat pump?
Start by locating the compressor 1 discharge temperature sensors and checking whether either has come loose from its mounting position on the discharge pipe. If a sensor has separated, reattach it firmly to the pipe surface and secure the mounting clip. If both sensors appear properly seated, inspect the wiring connections for looseness or corrosion, and test sensor resistance values to determine if a sensor has failed and needs replacement.
Will resetting my LG heat pump clear the E262 error code?
A reset may temporarily clear the fault code, but the error will return if the underlying cause has not been corrected. If a sensor has physically separated or failed, the temperature differential will exceed the 40 degree threshold again as soon as the compressor runs and the code will reappear. The sensor must be properly repositioned or replaced before the fault will clear permanently.