What the E297 error code actually means

The E297 code means your LG heat pump is having trouble switching between heating and cooling modes because a key internal valve is not working properly. This valve is responsible for reversing the direction refrigerant flows through the system, which is how the unit can both heat and cool your home. Until this issue is repaired, your heat pump may blow air at the wrong temperature or stop working altogether.

Diagnostic procedure

The full E297 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E297 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E297

Ranked by how often they cause this code
  1. 1Faulty 4-way valve solenoid coil
  2. 2Stuck or mechanically failed valve slide
  3. 3Wiring or connector fault at the solenoid
  4. 4Control board not sending actuation signal
  5. 5Low refrigerant charge affecting valve operation

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E297

What does E297 mean on a LG heat_pump?
E297 on an LG heat pump indicates a 4-way valve operation error. The 4-way reversing valve controls which direction refrigerant flows through the system, enabling both heating and cooling modes. This code means the control board has detected that the valve is not shifting correctly when the system attempts to change operating modes. The cause can be electrical, mechanical, or related to refrigerant charge level.
Is it safe to run my LG heat pump with an E297 error?
Running the unit with an active E297 error is not recommended. If the 4-way valve is stuck in the wrong position, the heat pump will operate inefficiently and may deliver heating when cooling is needed, or vice versa. More importantly, continued operation with a faulty valve can place abnormal stress on the compressor and potentially cause additional component damage. It is best to shut the unit down and have it diagnosed promptly.
Will resetting my LG heat pump clear the E297 error?
A power reset may temporarily clear the E297 code if the fault was caused by a one-time control glitch, but if the 4-way valve, solenoid coil, or wiring has an actual defect, the error will return as soon as the system attempts to switch modes again. Clearing the code without addressing the underlying cause does not fix the problem and may delay a diagnosis while the system operates in a degraded state.
Can I fix E297 on my LG heat pump myself?
Some electrical checks, such as inspecting wiring and connectors for damage or corrosion, can be performed by a knowledgeable DIYer with a multimeter. However, testing solenoid voltage during operation, checking refrigerant pressures, and replacing the 4-way valve or solenoid coil typically require a certified HVAC technician with the proper tools and EPA refrigerant handling certification. Attempting to open the refrigerant circuit without certification is illegal and dangerous.
How much does it cost to repair an E297 error on an LG heat pump?
Repair costs vary depending on the root cause. Wiring repairs or a solenoid coil replacement are typically the least expensive path, often ranging from around $150 to $400 including labor. Replacing the 4-way valve body itself is a more involved refrigerant-circuit repair and can range from roughly $400 to $900 or more depending on the unit size and technician rates in your area. A refrigerant recharge, if needed, adds additional cost.