LG Heat Pump Error Code E313

Fixed capacity compressor 2 discharge sensor error OPEN/SHORT

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E313 error code actually means

Your LG heat pump has detected a problem with a temperature sensor located on one of its compressors, the part that pressurizes the refrigerant. The sensor is either not sending a signal at all or is sending a signal that is out of the normal range, so the system has shut down to prevent damage. A technician will need to check the sensor wiring and the sensor itself to determine which has failed.

Diagnostic procedure

The full E313 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check sensor connector; measure resistance across terminals.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E313 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E313

Ranked by how often they cause this code
  1. 1Disconnected or loose sensor connector
  2. 2Failed discharge temperature sensor
  3. 3Damaged sensor wiring or harness
  4. 4Corroded or oxidized connector terminals
  5. 5Control board input circuit fault

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E313

What does E313 mean on a LG heat_pump?
E313 indicates a discharge temperature sensor error on the fixed capacity compressor 2 in the outdoor unit. The control board has detected a sensor signal voltage above 4.95V (open circuit, corresponding to a reading below -30°C) or below 0.5V (short circuit, corresponding to a reading at or above 151°C). This fault is only triggered when outdoor temperatures are above -10°C. The system shuts down to protect the compressor from unmonitored overheating.
Is it safe to keep running my heat pump with an E313 error?
No, you should not continue operating the unit with E313 active. The discharge temperature sensor protects compressor 2 from overheating by allowing the control system to monitor refrigerant conditions. Without a valid sensor reading, the system cannot detect a damaging overtemperature condition, which could result in compressor failure. The unit will typically prevent operation automatically when this fault is active.
How much does it cost to repair an E313 error on an LG heat pump?
Repair costs vary depending on what has failed. If only the connector needs cleaning or reseating, a service call fee of roughly $80 to $150 may cover the work. Replacing the discharge temperature sensor typically adds $30 to $100 in parts. If wiring repairs or control board replacement are needed, total costs can range from $200 to $600 or more depending on parts availability and labor rates in your area.
Can I fix E313 on my LG heat pump myself?
Some steps, like checking the sensor connector for looseness or visible damage, are accessible to a knowledgeable DIYer. However, measuring sensor resistance, tracing wiring faults, and replacing components in the outdoor unit typically require basic electrical tools and familiarity with HVAC systems. Because this fault involves a compressor protection sensor, it is recommended to have a qualified technician perform the repair if you are not comfortable with electrical diagnostics.
Will resetting the unit clear the E313 error?
A power reset may temporarily clear the fault display, but E313 will return if the underlying sensor, wiring, or connector problem has not been corrected. Because the fault condition is based on real-time voltage readings from the sensor circuit, the error will reappear as soon as the control board reads the signal again and finds it outside the valid range. Resetting without repairing the root cause does not resolve the problem.