LG Heat Pump Error Code E324

SUMP TEMP FIXED 3 sensor error OPEN/SHORT (detected when outdoor temp over -10°C; over 4.95V/-30°C or below 0.5V/151°C).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E324 error code actually means

Your LG heat pump is detecting a problem with one of its internal temperature sensors, specifically a sump temperature sensor that has either lost its connection or developed a short circuit. The system cannot get a valid temperature reading from this sensor, so it has shut down to prevent potential damage. A technician will need to inspect the sensor and its wiring to determine whether a simple connector repair or a sensor replacement is needed.

Diagnostic procedure

The full E324 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E324 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E324

Ranked by how often they cause this code
  1. 1Faulty or failed SUMP TEMP FIXED 3 sensor
  2. 2Loose, corroded, or disconnected wiring connector
  3. 3Damaged or broken sensor wiring harness
  4. 4Moisture or contamination in the connector
  5. 5Failed control board sensor input circuit

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E324

What does E324 mean on a LG heat_pump?
E324 indicates a fault with the SUMP TEMP FIXED 3 temperature sensor in the heat pump system. The control board has detected that the sensor's signal voltage is either above 4.95V (corresponding to a reading below -30 degrees Celsius, suggesting an open circuit) or below 0.5V (corresponding to a reading above 151 degrees Celsius, suggesting a short circuit). This fault is only triggered when outdoor temperatures are above -10 degrees Celsius, ensuring the detection is not a cold-weather false positive.
Is it safe to keep running my LG heat pump when E324 is displayed?
The heat pump will generally shut down or restrict operation when E324 is active, as the control system cannot reliably monitor sump temperatures without a valid sensor signal. Continuing to operate the unit while this fault is present could risk undetected temperature extremes within the refrigerant circuit. It is advisable to leave the unit off until the fault is diagnosed and resolved.
How much does it cost to repair an E324 error on an LG heat pump?
Repair costs depend on the root cause. If only a connector needs cleaning or reseating, the cost may be limited to a service call fee, typically in the range of 75 to 150 dollars. Replacing the SUMP TEMP FIXED 3 sensor itself generally costs between 50 and 150 dollars for the part plus labor. If the control board has failed and requires replacement, total costs including parts and labor can range from 400 to 900 dollars or more depending on the model.
Can I fix E324 on my LG heat pump myself?
Some causes of E324 are accessible to a knowledgeable DIYer, such as inspecting and reseating wiring connectors or checking for obvious damage to the sensor harness. However, confirming whether the sensor or control board has failed requires a multimeter to test sensor resistance and circuit voltage, which demands familiarity with electrical diagnostics. Refrigerant system work is not typically involved with this sensor fault, but working inside an outdoor unit still carries electrical hazard risks, so caution is essential.
Will resetting my LG heat pump clear the E324 error?
A power cycle reset may temporarily clear the displayed error, but if the underlying sensor or wiring fault still exists, the code will return once the system restarts and the outdoor temperature is above -10 degrees Celsius. A reset alone does not repair a faulty sensor, damaged wiring, or corroded connector. The root cause must be identified and corrected for the error to stay cleared.