mypros+
Error code reference

LG Heat Pump Error Code E332

Low pressure sensor OPEN/SHORT error (SHORT below 0.4V, OPEN over 4.7V; detected when compressor ready to operate).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E332 error code actually means

Your LG heat pump has detected a problem with the sensor that monitors refrigerant pressure on the low-pressure side of the system. The unit is preventing itself from starting in order to protect the compressor from potential damage. This is typically caused by a wiring problem or a faulty sensor, and a technician should inspect the sensor and its wiring before the unit is restarted.

Diagnostic procedure

The full E332 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check sensor wiring and connector.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E332 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E332

Ranked by how often they cause this code
  1. 1Loose or disconnected sensor connector
  2. 2Damaged or shorted sensor wiring
  3. 3Corroded or failed connector pins
  4. 4Failed low pressure sensor
  5. 5Control board input circuit fault

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E332

What does E332 mean on a LG heat_pump?
E332 indicates a low pressure sensor OPEN or SHORT error. The system detected that the sensor signal voltage was either below 0.4V (SHORT) or above 4.7V (OPEN) at the moment the compressor was preparing to start. The unit locks out to prevent compressor damage, and the fault usually points to a wiring, connector, or sensor problem.
Is it safe to keep running my heat pump with an E332 error?
The unit will generally prevent itself from running when E332 is active, which is the intended protective behavior. You should not attempt to bypass this lockout, as operating the compressor without verified low-side pressure monitoring can result in compressor damage. Leave the unit off until the fault is diagnosed and resolved.
How much does it cost to repair an E332 error on an LG heat pump?
If the issue is a loose or corroded connector, the repair may cost only a service call fee, typically in the range of $75 to $150. If the low pressure sensor needs replacement, parts and labor combined generally run between $150 and $350 depending on the model and local labor rates. A control board replacement, if needed, would be a higher cost repair in the range of $300 to $600 or more.
Can I fix the E332 error myself?
A knowledgeable DIYer can start by checking the low pressure sensor wiring and connector for loose connections, damaged insulation, or corrosion. If the wiring appears intact, measuring the sensor output voltage requires a multimeter and some familiarity with reading wiring diagrams. Refrigerant system work, however, requires EPA 608 certification and should be left to a licensed technician.
Will resetting the heat pump clear the E332 error?
A power reset may temporarily clear the error code, but if the underlying cause such as a faulty sensor, broken wire, or bad connector is still present, the fault will return when the compressor next attempts to start. Resetting without repairing the root cause does not fix the problem and can delay proper diagnosis.