SUMP TEMP FIXED 3 sensor error OPEN/SHORT

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E344 error code actually means

Your LG heat pump has detected a problem with a temperature sensor located in the sump area of the outdoor unit. The sensor is either not connected properly or has failed, so the system cannot get an accurate temperature reading and has stopped operating normally. A technician will need to inspect the sensor wiring and the sensor itself to find and correct the fault.

Diagnostic procedure

The full E344 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E344 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E344

Ranked by how often they cause this code
  1. 1Damaged or corroded sensor connector
  2. 2Failed NTC thermistor sensor
  3. 3Broken or chafed sensor wiring harness
  4. 4Sensor connector fully disconnected
  5. 5Faulty outdoor main control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E344

What does E344 mean on a LG heat_pump?
E344 indicates a SUMP TEMP FIXED 3 sensor fault in the outdoor unit, classified as either an open or short circuit condition. The error triggers when the outdoor temperature is above -10°C and the sensor signal voltage rises above 4.95V or drops below 0.5V. These voltage thresholds correspond to temperature readings below -30°C or above 151°C, both of which are outside any realistic operating range and signal a sensor or wiring failure.
Is it safe to run my LG heat pump with the E344 error active?
Operating the heat pump while E344 is active is not recommended. The system relies on the sump temperature sensor to manage refrigerant and compressor operation safely. Running the unit without a valid sensor reading can lead to improper operation and potential compressor or refrigerant circuit damage. The unit should remain off until the sensor fault is diagnosed and corrected.
Will resetting the heat pump clear the E344 error?
A power reset may temporarily clear the error code from the display, but if the underlying sensor fault, such as a failed thermistor, damaged wiring, or corroded connector, is still present, the E344 code will return once the system restarts and runs diagnostics. A reset alone does not repair the fault. The sensor circuit must be inspected and the defective component repaired or replaced to permanently resolve the error.
Can I fix the E344 error myself?
Some basic checks such as inspecting the sensor connector for corrosion, loose pins, or a disconnected plug can be performed by a knowledgeable homeowner with the system powered down safely. However, measuring thermistor resistance and tracing wiring faults inside the outdoor unit typically requires electrical knowledge and appropriate tools. Replacing the control board, if needed, should be performed by a qualified technician to avoid further damage.
How much does it cost to repair an E344 error on an LG heat pump?
Repair costs vary depending on the root cause. Connector cleaning or a replacement thermistor sensor typically falls in the range of $75 to $250 including labor. If the outdoor main control board requires replacement, costs can range from $400 to $900 or more depending on the model and local labor rates. Getting a diagnosis from a qualified technician before ordering parts is advisable.