What the E409 error code actually means

Your LG heat pump is detecting a problem with the temperature sensor on one of its compressors, specifically the sensor that monitors how hot the refrigerant gets as it leaves the compressor. The system has read a temperature value that is either impossibly high or impossibly low, which usually means the sensor or its wiring has failed. The unit will restrict or stop that compressor to protect it until the sensor issue is resolved.

Diagnostic procedure

The full E409 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check if sensor connector is separated from PCB; measure resistance across terminals.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E409 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E409

Ranked by how often they cause this code
  1. 1Disconnected sensor connector at PCB
  2. 2Failed discharge thermistor
  3. 3Damaged sensor wiring or harness
  4. 4Moisture or corrosion at connector terminals
  5. 5PCB input circuit fault

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E409

What does E409 mean on a LG heat_pump?
E409 indicates a discharge temperature sensor error on fixed capacity compressor 2. The outdoor unit PCB has detected a signal voltage above 4.95V or below 0.5V from that sensor, which corresponds to temperatures outside the physically plausible range of -30°C to 151°C. This condition is only flagged when the outdoor temperature is above -10°C. The system restricts compressor 2 operation to prevent damage until the sensor fault is corrected.
Is it safe to run my LG heat pump while E409 is active?
Continuing to operate the unit with an active E409 fault is not recommended. The discharge temperature sensor is a primary protection device for compressor 2, and without a reliable reading the system cannot prevent the compressor from overheating. Running the unit in this condition risks compressor damage, which is a significantly more expensive repair than resolving the sensor fault.
How much does it cost to repair an E409 error on an LG heat pump?
Repair costs vary depending on the root cause. If only the discharge sensor thermistor needs replacement, parts and labor typically range from around $100 to $300. A wiring harness repair or connector replacement may fall in a similar range. If the fault has caused compressor damage or the PCB requires replacement, costs can rise to $400 to $900 or more depending on the specific unit and local labor rates.
Can I fix E409 myself, or do I need a technician?
A knowledgeable DIYer can perform initial checks such as verifying the sensor connector is fully seated on the PCB and visually inspecting the sensor harness for obvious damage. However, measuring thermistor resistance accurately, interpreting the results against a resistance-temperature curve, and replacing components in a refrigerant system requires proper tools and, in many jurisdictions, EPA certification for refrigerant handling. If basic connector checks do not clear the fault, a qualified technician should complete the diagnosis.
Will resetting the unit clear the E409 error?
A power reset may temporarily clear the fault display, but the error will return if the underlying sensor or wiring problem has not been corrected. The PCB will re-evaluate the sensor voltage each time the system attempts to run compressor 2, and any reading outside the 0.5V to 4.95V range will re-trigger E409. A reset is useful only as a step to confirm whether the fault is intermittent after a repair has been made.