Outdoor unit discharge temperature 2 protection control.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E417 error code actually means

Your LG heat pump has detected that a temperature sensor near the compressor outlet on the outdoor unit is reading dangerously high, so the system shut itself down to protect the compressor. This is a safety feature that prevents serious and expensive internal damage. A technician should inspect the unit for refrigerant issues, dirty coils, or a blocked outdoor fan before restarting.

Diagnostic procedure

The full E417 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E417 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E417

Ranked by how often they cause this code
  1. 1Low refrigerant charge
  2. 2Blocked or dirty outdoor condenser coils
  3. 3Outdoor fan motor failure or reduced speed
  4. 4Faulty discharge temperature thermistor
  5. 5Compressor internal fault

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E417

What does E417 mean on a LG heat_pump?
E417 indicates that the outdoor unit's second discharge temperature sensor has triggered protection control because the compressor outlet temperature exceeded a safe operating threshold. The system shuts down or limits operation automatically to protect the compressor from heat-related damage. This code requires diagnosis of refrigerant charge, airflow conditions, the outdoor fan, and the discharge thermistor before the unit is restarted.
Is it safe to keep running my LG heat pump with an E417 error?
No. The E417 protection control exists specifically to prevent compressor damage from excessive heat. Attempting to bypass or repeatedly reset the unit without correcting the underlying cause risks permanent compressor failure, which is one of the most expensive components in the system. Leave the unit off until the root cause has been identified and repaired.
Will resetting my LG heat pump clear the E417 error code?
A power reset may temporarily clear the E417 code and allow the unit to restart, but the error will return if the underlying cause is not corrected. Repeatedly resetting the system without addressing the issue can cause progressive compressor damage. A reset should only be performed after verifying that airflow is unobstructed and conditions appear normal, and a full diagnostic should follow promptly.
Can I fix E417 myself without a technician?
Some causes, such as clearing debris from around the outdoor unit or cleaning dirty condenser coils, can be addressed by a knowledgeable homeowner. However, refrigerant-related diagnosis and recharging require EPA Section 608 certification and specialized equipment. Thermistor testing and compressor evaluation also typically require a trained technician with proper tools, so professional service is recommended for a thorough repair.
How much does it cost to repair an E417 error on an LG heat pump?
Repair costs depend heavily on the root cause. A simple coil cleaning or thermistor replacement might cost anywhere from $75 to $250 in parts and labor. Refrigerant leak repair and recharge can range from $200 to $600 or more depending on the refrigerant type and leak location. Compressor replacement is the most expensive scenario, typically ranging from $1,000 to $2,500 or higher including labor.