LG Heat Pump Error Code E423

SUMP TEMP FIXED 3 sensor error OPEN/SHORT

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E423 error code actually means

Your LG heat pump is reporting that a temperature sensor inside the outdoor unit has stopped working correctly, either because it has lost its connection or because something has caused it to send a bad signal. The system detected this problem because the sensor is reporting a temperature that is impossibly extreme, either far too cold or far too hot. Until the sensor issue is resolved, the heat pump may not operate normally.

Diagnostic procedure

The full E423 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E423 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E423

Ranked by how often they cause this code
  1. 1Corroded or loose sensor connector
  2. 2Failed NTC thermistor (sensor element)
  3. 3Damaged sensor wiring harness
  4. 4Moisture or debris contamination at the sensor body
  5. 5Faulty outdoor control PCB input circuit

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E423

What does E423 mean on a LG heat_pump?
E423 indicates a fault with the SUMP TEMP FIXED 3 temperature sensor in the outdoor unit. The system has detected an OPEN or SHORT condition in the sensor circuit, meaning the signal voltage has gone above 4.95V or below 0.5V. These voltage extremes correspond to temperature readings below -30°C or above 151°C, which are outside the valid operating range. The fault is only triggered when outdoor ambient temperature is above -10°C.
Is it safe to keep using my heat pump when E423 is displayed?
Operating the heat pump while E423 is active is not recommended. The sump temperature sensor provides data the control system uses to protect the compressor and manage refrigerant conditions in the outdoor unit. Running the system without a functioning sensor could allow conditions that damage the compressor or other components. It is best to address the fault before resuming normal operation.
How much does it cost to repair an E423 error on an LG heat pump?
Repair costs vary depending on the root cause. A simple connector cleaning or reseating may cost little beyond a service call fee, typically in the range of $75 to $150. Replacing the SUMP TEMP FIXED 3 sensor itself usually falls in the $100 to $300 range including parts and labor. If the outdoor control PCB requires replacement, costs can rise to $400 to $900 or more depending on the model and labor rates in your area.
Can I fix the E423 error myself, or do I need a technician?
Some basic checks, such as inspecting the sensor connector for corrosion, reseating loose connectors, and visually inspecting the wiring harness, can be done by a knowledgeable DIYer. However, testing sensor resistance, tracing a wiring fault, or diagnosing a PCB issue requires a multimeter and familiarity with refrigeration system components. If the sensor or board needs replacement, a qualified technician is recommended to ensure correct parts and safe reassembly.
Will resetting the heat pump clear the E423 error?
A power reset may temporarily clear the error display, but the code will return if the underlying sensor fault is still present. Because the system checks the sensor voltage continuously during operation, any persistent open or short condition will retrigger E423 once the unit restarts and ambient conditions meet the detection threshold above -10°C. A reset is useful for confirming whether a fault is intermittent, but it does not repair a failed sensor or damaged wiring.