LG Heat Pump Error Code E472

Outdoor unit compression rate 2 error.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E472 error code actually means

Your LG heat pump has detected that the outdoor compressor is not building pressure the way it should, which means the system cannot heat or cool your home effectively. This is often caused by low refrigerant, a refrigerant leak, or a compressor that is starting to fail. The unit has shut down to prevent further damage, and a technician should inspect it before you try to run it again.

Diagnostic procedure

The full E472 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E472 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E472

Ranked by how often they cause this code
  1. 1Low refrigerant charge
  2. 2Refrigerant leak
  3. 3Failing or worn compressor
  4. 4Restricted expansion valve or filter drier
  5. 5Faulty pressure sensor

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E472

What does E472 mean on a LG heat_pump?
E472 indicates an outdoor unit compression rate 2 error, meaning the heat pump has detected that the compressor is not achieving the expected pressure ratio between the suction and discharge sides of the refrigerant circuit. The system shuts down to prevent compressor damage. Common causes include low refrigerant, a refrigerant leak, a failing compressor, or a restricted component in the refrigerant circuit.
Is it safe to keep running my LG heat pump when E472 appears?
No, you should not continue operating the unit when E472 is active. The heat pump has already shut down as a protective measure, and attempting to force it to run could cause further damage to the compressor, which is one of the most expensive components in the system. Leave the unit off until a technician has diagnosed and resolved the underlying issue.
Will resetting my LG heat pump clear the E472 error code?
A power reset may temporarily clear the E472 code, but if the underlying cause such as low refrigerant, a refrigerant leak, or a compressor problem is not addressed, the error will return once the unit attempts to operate. Clearing the code without fixing the root cause can also risk additional compressor damage. A reset should only be used after a technician has diagnosed and repaired the fault.
Can I fix the E472 error on my LG heat pump myself?
Most causes of the E472 error require professional tools and certifications to repair properly. Diagnosing the fault accurately requires refrigerant manifold gauges, and any work involving refrigerant handling is regulated and must be performed by a licensed HVAC technician. Homeowners can check that the outdoor unit has good airflow and is free of debris, but the refrigerant circuit and compressor inspection should be left to a professional.
How much does it cost to repair an E472 error on an LG heat pump?
Repair costs vary significantly depending on the root cause. A refrigerant recharge after a leak repair can range from a few hundred dollars to over a thousand dollars depending on refrigerant type, leak location, and labor rates. Compressor replacement is the most expensive scenario, typically ranging from $1,000 to $2,500 or more including parts and labor. A service call for diagnosis alone generally costs between $75 and $150.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass