mypros+
Error code reference

LG Heat Pump Error Code P1

System down due to high temperature of COND sensor (condensate temperature of compressor reaches 67°C, system down after 6 detections within one…

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the P1 error code actually means

Your LG heat pump detected that a temperature sensor near the compressor got dangerously hot six times within one hour, so the system shut itself down to prevent damage. This usually happens when the outdoor unit cannot breathe properly, either because something is blocking the airflow around it or because the coils are dirty. The system will need the root cause corrected before it will run reliably again.

Diagnostic procedure

The full P1 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check for obstacles at air inlet/outlet of outdoor unit.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock P1 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of P1

Ranked by how often they cause this code
  1. 1Blocked air inlet or outlet on outdoor unit
  2. 2Dirty or fouled outdoor coil
  3. 3Outdoor fan motor failure or reduced speed
  4. 4Low or incorrect refrigerant charge
  5. 5Faulty or out-of-calibration COND sensor

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about P1

What does P1 mean on a LG heat pump?
The P1 code means the compressor's COND sensor detected a condensate temperature of 67°C or higher six times within one hour, causing the system to shut down as a protective measure. This indicates that heat is not being properly rejected at the outdoor unit. The system will not resume normal operation until the underlying cause is corrected and the fault is cleared.
Is it safe to keep running my heat pump with a P1 error?
No. The P1 code results in a full system shutdown, meaning the heat pump will not operate while the fault is active. Attempting to force continuous operation without addressing the overheating condition could cause compressor damage, which is a significantly more expensive repair. Allow the system to cool and investigate the cause before attempting to restart.
How much does it cost to repair a P1 error on an LG heat pump?
Repair costs vary widely depending on the cause. Clearing debris and cleaning the coil may cost little to nothing if done yourself, or $75 to $200 if a technician performs a maintenance visit. Replacing a faulty fan motor or capacitor typically runs $150 to $450 in parts and labor. If a refrigerant recharge or sensor replacement is needed, expect costs in the $200 to $600 range depending on refrigerant type, regional rates, and the extent of any leak repair required.
Can I fix the P1 error myself?
Some causes of the P1 code are DIY-friendly, particularly checking for and removing physical obstructions around the outdoor unit and cleaning a dirty outdoor coil. However, diagnosing a failed fan motor, checking refrigerant charge, or replacing a COND sensor requires technical knowledge and, in the case of refrigerant, licensed equipment. Start with the airflow and coil inspection, and call a technician if those steps do not resolve the fault.
Will resetting the heat pump clear the P1 error?
A power reset may clear the active fault and allow the system to restart, but if the root cause is not corrected, the system will detect six more high-temperature events within an hour and shut down again. A reset is useful for confirming whether the issue is intermittent or persistent, but it is not a solution on its own. Address the airflow, coil, fan, and refrigerant conditions before relying on a reset.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass