Forbid cooling mode operation when outdoor temperature below -5°C.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the P432 error code actually means

Your LG heat pump is preventing itself from running in air conditioning mode because it has detected that the outdoor temperature is too cold, below -5°C or 23°F. This is a built-in safety feature, not a breakdown. If the weather outside is warmer than that, the outdoor temperature sensor may need to be checked.

Diagnostic procedure

The full P432 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Not a product error; verify outdoor temperature sensor reading matches actual temperature.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock P432 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of P432

Ranked by how often they cause this code
  1. 1Actual outdoor temperature below -5°C
  2. 2Faulty outdoor ambient temperature sensor
  3. 3Damaged or corroded sensor wiring
  4. 4Loose or disconnected sensor connector at control board
  5. 5Control board misreading sensor input

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about P432

What does P432 mean on a LG heat_pump?
P432 on an LG heat pump indicates that cooling mode operation is being blocked because the outdoor temperature has been detected as being below -5°C (23°F). This is a built-in protective restriction, not a component failure. The unit will not run in cooling mode under these conditions by design. If the outdoor temperature is actually above -5°C, the outdoor temperature sensor should be checked for accuracy.
Is P432 on my LG heat pump a safety issue?
P432 itself is not a safety hazard. It is a protective feature that prevents the system from running the refrigerant circuit in cooling mode during very cold outdoor conditions. The restriction is intentional and keeps the unit from operating outside its designed temperature range. If you suspect the code is appearing due to a faulty sensor rather than actual cold temperatures, addressing the sensor issue is straightforward and low risk.
Will resetting my LG heat pump clear the P432 code?
Resetting the unit may temporarily clear the P432 display, but the code will return if the outdoor temperature is still below -5°C or if the underlying sensor issue has not been resolved. Because P432 is a condition-based restriction rather than a latched fault, the control board will reinstate the cooling lockout as soon as it reads a temperature below the threshold. A permanent fix requires either waiting for warmer weather or correcting the sensor or wiring problem causing the inaccurate reading.
How do I fix P432 on my LG heat pump?
Start by verifying the actual outdoor temperature with a thermometer near the outdoor unit and compare it to the temperature reading shown by the system. If the outdoor temperature is genuinely below -5°C, no fix is needed as the unit is working correctly. If temperatures are above -5°C but the code persists, inspect the outdoor ambient temperature sensor, its wiring, and the connector at the control board for damage, corrosion, or loose connections. Replace the sensor if its resistance reading does not match the expected value for the current temperature.
How much does it cost to repair a P432 error on an LG heat pump?
If the code is appearing because outdoor temperatures are genuinely below -5°C, there is no repair cost at all. If a faulty outdoor ambient temperature sensor is the cause, sensor replacement parts typically range from around $20 to $80 depending on the specific model, plus labor if a technician is involved. Wiring repairs, if needed, are usually lower in cost than sensor replacement.