LG Heat Pump Error Code P511

Compressor down by low pressure sensor protection control 2.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the P511 error code actually means

Your LG heat pump has shut itself off to protect the compressor because it detected unusually low pressure inside the refrigerant system. This can happen if the system is low on refrigerant, if airflow is blocked, or if a sensor or valve has malfunctioned. The unit will not run again until the underlying cause is identified and corrected.

Diagnostic procedure

The full P511 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock P511 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of P511

Ranked by how often they cause this code
  1. 1Low refrigerant charge due to a leak
  2. 2Restricted or dirty air filters and coils
  3. 3Faulty or stuck expansion valve (TXV or EEV)
  4. 4Defective low pressure sensor
  5. 5Outdoor unit airflow obstruction

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about P511

What does P511 mean on a LG heat pump?
P511 means the heat pump has shut down the compressor due to low pressure sensor protection control 2. The system detected that suction-side refrigerant pressure fell below a safe threshold, so the control board forced a shutdown to prevent compressor damage. Common causes include refrigerant loss, blocked airflow, a faulty expansion valve, or a defective pressure sensor. A qualified technician should diagnose the root cause before the unit is restarted.
Is it safe to keep using my LG heat pump when P511 is showing?
No. The P511 code indicates the system has already shut itself down to protect the compressor from damage. Attempting to repeatedly restart the unit and force it to run without addressing the underlying cause can result in compressor failure, which is one of the most expensive components in the system. Leave the unit off and schedule a service call.
Will resetting my LG heat pump clear the P511 error?
A power cycle reset may temporarily clear the P511 fault and allow the unit to restart, but if the underlying cause such as a refrigerant leak or faulty component is still present, the error will return and the compressor will shut down again. Repeated resets without fixing the root cause risk permanent compressor damage. A proper repair addressing the source of the low pressure condition is required for the fault to stay cleared.
Can I fix a P511 error on my LG heat pump myself?
Some basic checks, like inspecting and replacing dirty air filters or clearing debris from the outdoor unit, can be done without professional help. However, diagnosing refrigerant leaks, recharging the system, or replacing components like the expansion valve or pressure sensor requires EPA Section 608 certification and specialized tools. Attempting refrigerant-side repairs without proper training and equipment is unsafe and may be illegal.
How much does it cost to repair a P511 error on an LG heat pump?
Repair costs vary widely depending on the root cause. Cleaning coils and replacing filters may cost between $75 and $200 for a service visit. Refrigerant leak repair and recharge can range from $300 to $800 or more depending on leak location and refrigerant type. Expansion valve replacement typically falls between $250 and $600 in parts and labor. Pressure sensor replacement is generally less expensive, often in the $150 to $400 range.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass