LG Heat Pump Error Code P512

Compressor down by low pressure sensor protection control 3.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the P512 error code actually means

Your LG heat pump has shut itself off because it detected that the pressure inside the refrigerant system dropped too low, which can damage the compressor if it keeps running. This is the system protecting itself after detecting a repeated or serious low-pressure problem. A technician will need to check the refrigerant level, airflow, and sensors to find the root cause.

Diagnostic procedure

The full P512 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock P512 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of P512

Ranked by how often they cause this code
  1. 1Low refrigerant charge (refrigerant leak)
  2. 2Restricted or blocked metering device
  3. 3Evaporator coil icing or restricted airflow
  4. 4Faulty low pressure sensor
  5. 5Wiring or connector fault at the pressure sensor

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about P512

What does P512 mean on a LG heat_pump?
P512 means the compressor has been shut down by the low pressure sensor protection control, specifically protection sequence 3. The system detected that refrigerant suction pressure dropped below a safe threshold and locked out the compressor to prevent damage. This fault indicates a persistent or escalating low-pressure condition rather than a simple one-time dip. A technician should inspect refrigerant charge, airflow, the expansion device, and the low pressure sensor itself.
Is it safe to keep using my LG heat pump when P512 is displayed?
No, you should not continue operating the unit while P512 is active. The system has already shut down the compressor as a protective measure. Forcing the unit to run under low-pressure conditions can cause severe compressor damage, including loss of lubrication and internal mechanical failure. Leave the unit off until the root cause has been diagnosed and corrected.
How much does it cost to repair a P512 error on an LG heat pump?
Repair costs vary depending on the cause. A refrigerant recharge following a leak repair can range from $200 to $600 or more depending on refrigerant type and the extent of the leak. Replacing a low pressure sensor typically costs between $100 and $250 including labor. A failed expansion valve replacement can range from $250 to $500 or higher. Diagnostic service calls generally run $75 to $150 before any parts or repairs.
Can I fix P512 on my LG heat pump myself?
Some causes, such as a dirty air filter or blocked airflow, can be corrected without professional help. However, if the issue involves refrigerant levels, a refrigerant leak, a faulty expansion valve, or a failed pressure sensor, a licensed HVAC technician is required. Refrigerant handling legally requires EPA 608 certification. Attempting refrigerant work without proper credentials and equipment is both illegal and unsafe.
Will resetting the unit clear the P512 error code?
A power reset may temporarily clear the fault and allow the system to restart, but the code is likely to return if the underlying problem has not been fixed. Because P512 is classified as protection control sequence 3, the system has already cycled through earlier protective attempts, making a simple reset unlikely to provide a lasting solution. Address the root cause before relying on a reset.