mypros+
Error code reference

LG Heat Pump Error Code P711

Compressor down by high pressure sensor protection control 1.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the P711 error code actually means

Your LG heat pump has shut itself off because the pressure inside the refrigerant system got too high, which is a built-in safety feature to protect the compressor from damage. This can happen because of blocked airflow, a stuck valve, or a component that controls refrigerant flow not working correctly. A technician will need to inspect several parts of the system to find the root cause before it is safe to restart the unit.

Diagnostic procedure

The full P711 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check service valves; check PWM valve coil and connector; check indoor/outdoor fan operation.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock P711 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of P711

Ranked by how often they cause this code
  1. 1Closed or partially closed service valves
  2. 2Faulty PWM valve coil or connector
  3. 3Outdoor fan not operating correctly
  4. 4Indoor fan not operating correctly
  5. 5Refrigerant overcharge or non-condensable gases

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about P711

What does P711 mean on a LG heat pump?
P711 means the compressor has been shut down by the high pressure sensor protection control. The system detected refrigerant pressure on the high side of the circuit exceeding safe operating limits and halted the compressor to prevent damage. Common triggers include closed service valves, a malfunctioning PWM valve, or inadequate fan airflow across the coils. A technician should inspect all three areas before restarting the unit.
Is it safe to keep running my LG heat pump with a P711 error?
No. The P711 code indicates the system has already shut down the compressor as a protective measure. Attempting to bypass or repeatedly reset the unit without addressing the underlying cause risks serious compressor damage, refrigerant line failures, or other costly component failures. The system should remain off until the root cause has been diagnosed and corrected.
Will resetting my LG heat pump clear the P711 error?
A power reset may temporarily clear the P711 fault and allow the system to restart, but if the underlying cause is not corrected, the error will return and the compressor will shut down again. Repeated high-pressure shutdowns can accelerate wear on the compressor and other components. A reset should only be performed after the cause has been identified and resolved, not as a substitute for diagnosis.
Can I fix the P711 error myself?
Some preliminary checks, such as confirming service valves are fully open and verifying that the indoor and outdoor fans are running without obstructions, can be done without special tools. However, inspecting the PWM valve coil resistance, testing the high pressure sensor, and diagnosing refrigerant charge issues require gauges and electrical diagnostic equipment that most homeowners do not have. For anything beyond basic visual checks, a qualified HVAC technician should handle the repair.
How much does it cost to repair a P711 error on an LG heat pump?
Repair costs vary widely depending on the root cause. A simple service valve adjustment or connector repair may cost between $75 and $200 for a service call. Replacing a PWM valve coil or fan motor can range from $150 to $500 or more depending on parts and labor rates in your area. If the compressor has already sustained damage from repeated high-pressure events, costs can be significantly higher.