mypros+
Error code reference

LG Heat Pump Error Code P716

Outdoor unit discharge temperature 1 protection control.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the P716 error code actually means

Your LG heat pump detected that the hot refrigerant gas leaving the compressor in the outdoor unit got too hot, so the system shut itself down to prevent damage. This is a safety feature designed to protect one of the most expensive components in the system, the compressor. A technician will need to find out why the system is overheating, which could involve checking refrigerant levels, cleaning the outdoor unit, or testing a temperature sensor.

Diagnostic procedure

The full P716 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock P716 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of P716

Ranked by how often they cause this code
  1. 1Low refrigerant charge
  2. 2Blocked or dirty outdoor coil
  3. 3Outdoor fan motor failure or reduced speed
  4. 4Faulty discharge temperature sensor
  5. 5Refrigerant flow restriction

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about P716

What does P716 mean on a LG heat_pump?
P716 indicates that the outdoor unit discharge temperature has reached a level requiring protection control. The discharge temperature is the temperature of refrigerant gas exiting the compressor, and when it rises too high, the system shuts down to prevent compressor damage. This code points to issues affecting heat rejection or refrigerant flow in the outdoor unit. A qualified technician should diagnose the root cause before restarting the system.
Is it safe to keep running my LG heat pump with a P716 error?
No, you should not attempt to bypass or continuously restart the system while P716 is active. The protection control exists specifically to prevent compressor failure, which can result from sustained high discharge temperatures. Repeatedly overriding the error without addressing the root cause risks destroying the compressor, which is the most costly component in the system.
How much does it cost to repair a P716 error on an LG heat pump?
Repair costs vary significantly depending on the root cause. A coil cleaning or minor service call might range from around 100 to 250 dollars, while refrigerant recharge can add another 150 to 400 dollars or more depending on refrigerant type and the amount needed. A fan motor replacement typically falls in the range of 200 to 500 dollars including labor, and a compressor replacement, if required, can cost anywhere from 800 to over 2000 dollars. Getting a proper diagnosis first is the best way to understand the scope of the repair.
Can I fix P716 on my LG heat pump myself?
Some basic checks are safe for homeowners, such as clearing debris from around the outdoor unit and making sure the outdoor fan is spinning freely. However, diagnosing refrigerant levels, testing the discharge temperature sensor, or repairing the fan motor requires tools and certifications that most homeowners do not have. It is best to contact a licensed HVAC technician to properly diagnose and repair the underlying cause.
Will resetting the unit clear the P716 error code?
A power reset may temporarily clear the code and allow the unit to restart, but if the underlying condition causing high discharge temperatures has not been resolved, the error will return. Resetting without a proper repair can accelerate compressor wear. A technician should identify and fix the root cause before the system is returned to service.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass