What the P721 error code actually means

Your LG heat pump detected that a critical area near the compressor got dangerously hot and stayed that way for too long, so the system shut down to protect itself from serious damage. This is a safety feature designed to prevent a costly compressor failure. A technician will need to inspect the compressor, a valve that controls flow, and a temperature sensor to find the root cause.

Diagnostic procedure

The full P721 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check compressor loading/unloading via S-net; check PWM valve; check temperature sensor attachment.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock P721 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of P721

Ranked by how often they cause this code
  1. 1Compressor overloading without proper unloading cycles
  2. 2Faulty or stuck PWM valve
  3. 3Temperature sensor poor attachment or failure
  4. 4Refrigerant charge issues
  5. 5Blocked airflow around the outdoor unit

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about P721

What does P721 mean on a LG heat pump?
P721 indicates that the outdoor unit's compressor sump temperature reached 95°C and stayed there for at least 5 minutes, triggering the SUMP DOWN 1 protection control. The unit shuts down automatically to prevent compressor damage. The fault points to issues with compressor loading behavior, the PWM valve, or the sump temperature sensor. A technician should use S-net diagnostics to investigate the root cause before restarting the system.
Is it safe to keep running my heat pump when P721 is displayed?
No. The P721 fault represents a protective shutdown triggered by dangerously high sump temperatures. Continuing to operate the unit or bypassing the fault without resolving the underlying cause can result in compressor failure, which is one of the most expensive repairs possible on a heat pump system. Leave the unit off until the fault has been properly diagnosed and corrected.
Will resetting the unit clear the P721 error code?
A power reset may temporarily clear the P721 fault and allow the unit to restart, but the code will return if the underlying condition causing the sump to overheat is still present. Because this fault involves a sustained temperature threshold, the thermal issue must be resolved to prevent repeat shutdowns. Repeated resets without repair increase the risk of permanent compressor damage, so a reset should only be used as part of a supervised diagnostic process.
Can I fix a P721 error myself, or do I need a technician?
Some preliminary checks, such as clearing debris from around the outdoor unit or visually inspecting the temperature sensor for obvious looseness, can be done without specialized tools. However, diagnosing the PWM valve and compressor loading behavior requires S-net software access and refrigerant handling knowledge that a certified HVAC technician should perform. Attempting to bypass or ignore this fault risks permanent compressor damage.
How much does it cost to repair a P721 fault on an LG heat pump?
Repair costs vary widely depending on the root cause. If the fix is a reattached temperature sensor or a refrigerant adjustment, you may be looking at a service call fee in the range of $100 to $300. A failed PWM valve replacement could run $300 to $700 including labor. If the compressor has been damaged from sustained overheating, replacement costs can range from $1,200 to $3,000 or more depending on the unit size.