Outdoor unit reverse phase detection 2 error.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the P762 error code actually means

Your LG heat pump has detected that the electrical power coming into the outdoor unit is wired in the wrong order, which could seriously damage the system if it were allowed to run. This is a safety shutdown designed to protect the compressor from spinning the wrong direction. A licensed electrician or HVAC technician will need to correct the wiring before the unit will operate again.

Diagnostic procedure

The full P762 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock P762 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of P762

Ranked by how often they cause this code
  1. 1Incorrect phase wiring at installation
  2. 2Utility or electrical service work
  3. 3Loose or miswired disconnect connection
  4. 4Faulty phase detection relay or control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about P762

What does P762 mean on a LG heat_pump?
P762 indicates that the outdoor unit has detected a reverse phase condition in the incoming three-phase power supply. The control board monitors the rotational sequence of the three power phases, and when that sequence does not match the required order, the unit shuts down to prevent compressor damage. This is a protective fault and the unit will not operate until the phase sequence is corrected.
Is it safe to keep running my LG heat pump with the P762 error?
The unit will not run while P762 is active, which is actually a safety feature. If the lockout were bypassed and the unit operated on a reversed phase sequence, the compressor could rotate in the wrong direction, leading to severe and often irreparable internal damage. Do not attempt to bypass or override this fault.
How much does it cost to fix the P762 error on an LG heat pump?
If the fix is simply swapping two supply conductors at the disconnect, electrician labor costs are typically in the range of $75 to $200 depending on your area and the complexity of the access. If the fault is traced to a defective phase detection relay or outdoor control board, parts and labor costs can range from $300 to $800 or more. Getting a diagnosis from a certified HVAC technician first will help identify whether the issue is a simple wiring correction or a component failure.
Can I fix the P762 error myself?
Correcting a reverse phase condition requires working inside the disconnect box or supply panel with high-voltage three-phase power, which is dangerous and in many jurisdictions must be performed by a licensed electrician or HVAC technician. If you are comfortable and qualified working with three-phase electrical systems, you can use a phase rotation meter to confirm the issue and swap two of the supply conductors to correct the sequence. Most homeowners should not attempt this repair without professional assistance.
Will resetting the unit clear the P762 error code?
Resetting the outdoor unit will not permanently clear P762 if the underlying phase sequence problem has not been corrected. The fault will return immediately upon restart because the phase detection circuit will detect the same reversed phase condition. The wiring must be corrected first, after which the unit can be reset and restarted normally.