LG Heat Pump Error Code t4

Error of liquid refrigerant pipe (COND OUT) temperature sensor (OPEN/SHORT)

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the t4 error code actually means

Your LG heat pump is detecting a problem with the temperature sensor that monitors refrigerant leaving the condenser coil. The system cannot read a valid temperature from that sensor, so it has shut down to protect itself. This is typically a sensor or wiring issue rather than a refrigerant problem.

Diagnostic procedure

The full t4 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check if sensor connector is departed from PCB; measure resistance across sensor terminals and compare to resistance table.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock t4 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of t4

Ranked by how often they cause this code
  1. 1Disconnected sensor connector at PCB
  2. 2Failed thermistor sensor (open or short circuit)
  3. 3Damaged wiring harness or broken wire
  4. 4Corroded or contaminated connector terminals
  5. 5Faulty control PCB input circuit

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about t4

What does t4 mean on a LG heat_pump?
The T4 error code indicates a fault in the liquid refrigerant pipe temperature sensor at the condenser outlet. The PCB has detected a voltage signal outside the valid range, either above 4.9V (open circuit, below -50 degrees C) or below 0.4V (short circuit, above 93 degrees C). This typically points to a disconnected connector, a failed thermistor, or a damaged wiring harness. The system halts operation when this fault is active to protect the refrigerant circuit.
Is it safe to keep running my LG heat pump with a T4 error?
The heat pump will generally lock out operation when T4 is active, so continued running may not be possible without clearing the fault first. Attempting to bypass or ignore the error is not advisable, as the condenser outlet sensor provides data the control system relies on for safe refrigerant management. Address the fault before resuming normal operation.
How much does it cost to repair a T4 error on an LG heat pump?
Repair costs vary depending on the root cause. Replacing a thermistor sensor typically involves parts costs in the range of 20 to 80 dollars plus labor, while a wiring harness repair may add additional labor time. If the control PCB requires replacement, total costs can range from 300 to 700 dollars or more depending on the unit and labor rates in your area. Diagnosis by a certified technician is the best way to get an accurate estimate for your specific situation.
Can I fix the T4 error myself on my LG heat pump?
A knowledgeable DIYer can perform initial checks such as reseating the sensor connector at the PCB and visually inspecting the wiring for obvious damage. Resistance testing with a multimeter is also straightforward if you have access to the sensor terminals and the correct resistance table. However, if the sensor needs replacement or the PCB is suspected, a qualified HVAC technician is recommended, especially since accessing internal refrigerant system components may require certification.
Will resetting my LG heat pump clear the T4 error?
A power reset may temporarily clear the T4 fault display, but the error will return if the underlying sensor or wiring issue has not been resolved. The PCB continuously monitors the sensor voltage during operation, so any persistent open or short circuit condition will re-trigger the fault shortly after restart. A reset is useful for confirming a repair was successful, but it is not a fix on its own.