Sub-Zero Freezer Error Code 20
Defrost under-heat with no voltage feedback through Gray/White wire at defrost start.
SourceSub-Zero 700-3 Tall Freezer - Service Manualp. 3-24, 8-3
Diagnostic procedure
The full 20 procedure
Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.
MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
With cold evaporator (<10°F), initiate Manual Defrost, then Diagnostic Mode to observe evap temp. If temp exceeds 45°F and defrost lasts longer than 5 minutes, error is false. Otherwise check Gray/White wire continuity from defrost heater to J4-4.
SourceSub-Zero Freezer - Service Manual: Integrated (700-2) Seriesp. 3-24, 8-4