Sub-Zero Refrigerator Error Code 50 U 87

Water flow meter did not detect flow.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 50 U 87 error code actually means

Your Sub-Zero refrigerator tried to run water for the ice maker or water dispenser, but the sensor that tracks water movement detected nothing flowing through the line. This usually means there is a water supply problem, a blockage somewhere in the water path, or the sensor itself is dirty or broken. Until the issue is resolved, the ice maker or dispenser will not function normally.

Diagnostic procedure

The full 50 U 87 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Verify water pressure, water flow, and that flow meter is not blocked or dirty.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 50 U 87 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 50 U 87

Ranked by how often they cause this code
  1. 1Low or interrupted water supply pressure
  2. 2Blocked or dirty flow meter
  3. 3Clogged water inlet valve screen
  4. 4Kinked or pinched water supply line
  5. 5Failed water inlet valve solenoid

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 50 U 87

What does 50 U 87 mean on a Sub-Zero refrigerator?
Error code 50 U 87 means the water flow meter did not detect any water movement during a fill cycle. The refrigerator monitors water flow with an inline sensor, and this code appears when that sensor registers zero flow after the control board commands water to run. The fault points to a supply pressure issue, a blockage, or a problem with the flow meter or inlet valve itself.
Is it safe to keep using my Sub-Zero refrigerator while error 50 U 87 is active?
The refrigerator itself will continue to cool normally while this code is active, so food safety is not immediately compromised. However, the ice maker and water dispenser will not function correctly until the water flow issue is resolved. Leaving the fault unaddressed for an extended period can allow ice maker components to run dry and wear prematurely.
How much does it cost to repair a Sub-Zero refrigerator showing error 50 U 87?
Repair costs vary depending on the cause. If the fix is simply opening a shutoff valve or clearing a kinked line, there is no parts cost involved. Replacing a clogged inlet valve screen is inexpensive, typically in the range of a few dollars to around twenty dollars for the part. A new flow meter or water inlet valve assembly on a Sub-Zero unit can cost anywhere from roughly sixty to over two hundred dollars for parts alone, with additional labor costs if a technician performs the repair.
How do I fix error code 50 U 87 on my Sub-Zero refrigerator?
Start by confirming the water supply shutoff valve is fully open and that household water pressure is adequate at the refrigerator connection. Next, inspect the water supply line for kinks, check the inlet valve screen for sediment buildup, and examine the flow meter for debris or mineral scale on the impeller. If cleaning does not resolve the fault, the flow meter or water inlet valve may need to be replaced.
Will resetting the refrigerator clear error code 50 U 87?
A reset may temporarily clear the displayed code, but if the underlying water flow problem has not been corrected the fault will return as soon as the refrigerator attempts another fill cycle. The code should only be considered resolved after the root cause, such as a blocked flow meter, low pressure, or a faulty inlet valve, has been diagnosed and corrected.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass