Whirlpool Refrigerator Error Code F3E8

External RH (humidity) sensor failure (must combine with ambient temperature sensor); flipper mullion heater…

External RH (humidity) sensor failure (must combine with ambient temperature sensor); flipper mullion heater will run at 100% (10 W).

First step from the service manual

Run Service Test 104 for humidity reading and Service Test 12 for ambient temperature; if no reading check wiring to HMI from sensor, then change sensor if wiring is good.