mypros+
Error code reference

Whirlpool Refrigerator Error Code F3E9

Ambient temperature sensor failure; mullion flipper heater will run at 100% (10 W).

Ambient temperature sensor failure; mullion flipper heater will run at 100% (10 W).

First step from the service manual

Run Service Test 12; display reads current temperature in degrees Celsius; SH indicates shorted, OP indicates open; check wiring to HMI board and change sensor if no wiring issue found.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for F3E9.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required