Model reference
Admiral 1172WL-30K
Cooktop
4 documents20 error codes12 service modes
Available documentation
Service Manual
- Job Aid - 4322334 (L-64)12 pg
- Instruction Sheet - 854371916 pg
Tech Sheet
- Tech Sheet 8543719 110 2506650016 pg
Tech Tip
- Instruction Sheet - 852220612 pg
MyPros+ Max
Diagnose your Admiral 1172WL-30K.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (20)
CodeMeaning
CAAverage current limit trip; a 2-second average current draw greater than 5.55…CECommunications error; breakdown in communication between the machine controller…CIInstantaneous current limit trip; a spike of 26 Amps was detected instantly at…ErProcessor reset error; the control failed to save cycle information during a…F1E3ACU relay failure.F1E4MW (Microwave) Relay error.F2E1Keypad stick failure.F4E3Hood NTC (thermistor) failure.F4E4Humidity sensor error.F4E9MW relay synchronization error.F5E2Open Door motor failure.F6E1ACU/HMI communication fault.FLFlood/overfill condition detected when excessive water in the tub causes the…LdLong drain; it takes longer than 5 minutes to pump out water to the point where…LFLong fill; the water fill time exceeded 10 minutes, causing the water valves to…LSLid switch error; the control cannot detect lid switch opening/closing…obOff balance; the motor controller detected an unrecoverable off-balance…PFPower failure detected during a running cycle; the washer lost power mid-cycle.SLSuds lock; excessive suds detected and the unit was unable to clean out suds…SrStuck relay; the relay has failed in the closed position so the machine…Service modes (12)
- ATC Wash Fill Test (Test 2)["Set the Water Temperature Switch to ATC-controlled Warm/Cold","Set the Timer in the Wash cycle…
- Automatic Service DiagnosticsControl must be in Off state. Perform Key Dance within 5 seconds
- Automatic Service Diagnostics ModeWith the machine in Standby Mode, press SOAK
- Console Keypad and LED TestControl must be in Off state. Perform Key Dance within 5 seconds
- Console Switches and Indicators TestWith the machine in Standby Mode, press SOAK
- Manual Diagnostic ModeWith the machine in Standby Mode, press SOAK
- Manual DiagnosticsControl must be in Off state. Perform Key Dance within 5 seconds
- Non-ATC Wash Fill Test (Test 1)["Set the Timer for the Wash cycle","Start the washer and the tub will begin filling with…
- Nutate and Recirculate TestControl must be in Off state. Perform Key Dance within 5 seconds
- Sales Demo ModePress SOAK
- Spin and Drain TestControl must be in Off state. Water should be present in the unit. Perform Key Dance within 5…
- Water Inlet and Dispenser Valve Operating PS TestControl must be in Off state. Perform Key Dance within 5 seconds
Full entry steps, exit procedures, and test sequences are available in Max.
Related Admiral cooktop models
78,000+ service manuals · 160,000+ error codes · 55+ brands