mypros+
Model reference

Admiral MEA15E-9P-P4

Microwave

7 documents89 error codes24 service modes

Available documentation

Tech Sheet

  • tech sheet w11359201 reva2 pg
    Covers this model
  • tech sheet w11279377 revA20 pg
    Covers this model
  • Tech Sheet16 pg
    Covers this model
  • TechSheet W11175370 REVA2 pg
    Covers this model
  • Tech Sheet - W11193638 - Rev A (EN,FR)24 pg
    Covers this model
  • Tech Manual24 pg
    Covers this model
  • Tech Sheet - W10811273 - Rev B5 pg
    Covers this model
MyPros+ Max

Diagnose your Admiral MEA15E-9P-P4.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (89)

View all 89 error codes
dULid Unlock FailureE0No errors present in the ice maker.E1Ice maker errorE2Ice maker errorE3Ice maker errorE4Ice maker errorE5Ice maker errorE6Manufacturing codeErManufacturing codeF 1Pressure Signal Out-of-RangeF 2Keypad/User Interface FailureF 40ATC Thermistor Open/ShortF 41Motor RPS Thermistor Open/ShortF 42Heater in unknown stateF 43Heater is continuously ONF 44Heater cannot be turned ONF 50Motor StalledF 51Motor RPS FailureF 52Motor Stop FailureF 53Motor Control OvertempF 54Motor Control OvercurrentF 72Basket Re-engagement FailureF0E0No error(s) foundF1E0Internal errorF1E1Internal errorF1E3Internal errorF1E4Microwave ACU PCBA failure.F1E5Internal errorF2E0Keypad disconnected from the control.F2E1Stuck key failure on touch panel.F3E0Upper main oven sensor shorted or open.F3E1Lower oven sensor open or shorted.F3E2Warming drawer sensor shortedF3E3Meat probe sensor shorted.F4E1Cavity temperature sensor failure (FC NTC).F4E2Microwave internal temperature sensor fault.F4E4Humidity sensor error.F5E0Door and latch switch do not agree.F5E1Door latch not operating.F6E0Lost communication between user interface and appliance manager.F6E1Cook oven over temperature condition.F6E2Clean oven over temperature condition.F6E3Mini oven/warm drawer over temperatureF6E4User interface and appliance manager mismatch.F6E5No cavity size command programmed.F7E0Water is not high enough or water did not boil fast enough in the steam system.F7E1Boiler over temperature condition.F7E2Boiler NTC temperature sensor out of range.F7E3Improper filter resetF7E4Conductivity sensor not connected.F8E5Exhaust air temperature detection failure from Hood NTC.HCHot, Cold ReversedLdLong DrainLFLong FilllidOpen/Close LidoLOverloadedPoPump OutSdSuds DetectionuLUnbalanced Load

Service modes (24)

  • Automatic Diagnostic Test Mode["Ensure washer is not currently running a cycle (in-progress screen should not be…
  • Beep TogglePress and hold the Hi Temp button for 3 seconds (a tone sounds).
  • Cavity size programming1
  • Clear last error code1
  • Console and Indicators Diagnostic Test Mode["Ensure washer is not currently running a cycle and LCD is on.","Press the Power/Cancel button and…
  • Control LockPress and hold the Control Lock button for 5 seconds to toggle on/off.
  • diagnostic["Plug in microwave oven or reconnect power.","Press Cancel button to reach Standby mode (colon ':'…
  • Diagnostic / Test Mode["Plug in microwave oven or reconnect power and press the Cancel keypad to standby (colon…
  • Diagnostic mode1
  • Diagnostic/Test Mode["Plug in microwave oven or reconnect power.","Press CANCEL to enter Standby mode (display shows…
  • Diagnostics / Test Mode["Plug in microwave oven or reconnect power.","Press CANCEL to reach standby (display shows…
  • Diagnostics Menu - Extended Mode1. Enter Diagnostics Mode (OFF, OFF, START). 2. From the Diagnostics Main Menu, access sub-menus
  • Diagnostics Mode["Plug in microwave oven or reconnect power and press CANCEL to Standby (':')","Close door, then…
  • Error Code ReadingEnter Service Diagnostics mode (1-2-3-1-2-3-1-2-3)
  • Fahrenheit to Celsius conversionPress OPTIONS and then '1' to toggle temperature between Fahrenheit and Celsius settings.
  • Manual Diagnostic Test Mode["Read and perform steps 1 and 2 of Activation of Automatic Diagnostic Test Mode (enter Service…
  • Oven temperature calibration adjustment1
  • Pressure Transducer Calibration["Enter Manual Diagnostic Test Mode.","From the Component Activation screen, select the 'Pressure'…
  • Quick Advance Mode (Customer Cycles)Press HIGH TEMP
  • Rapid Advance Mode (Customer Cycles)Press HIGH TEMP
  • Sabbath Mode activation (one-time enable)1
  • Saved Fault Codes["Enter Service Mode (Sound and Display > Service Mode > 5, 6, 5, 6 > Enter).","From the Diagnostic…
  • Service Diagnostics Cycle1
  • Service Diagnostics Mode["Ensure refrigerator is not in lockout mode.","Press SW1 and SW2 simultaneously for 3…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass