Model reference
AGA TC5
Range
1 document92 error codes8 service modes
Available documentation
Installation Guide
- AGA TOTAL CONTROL Installation Guide26 pg
MyPros+ Max
Diagnose your AGA TC5.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (92)
CodeMeaning
E10No water fillingE11No water fillingE13Not enough waterE20No drainingE21No drainingE23Incongruence between drainpump and electronicE24Drain pump triac sensing failureE30Pressure sensor defectE31Pressure sensor defectE32Calibration problems with pressure sensorE33Incongruence between pressure switch Niv.1 and antiboil level 1, or…E34Incongruence between pressure sensor and antiboil level 2 (fault for time…E35Safety level (pressure sensor)E36Antiboil 1 sensing failureE37No pressure differences detectedE38Pressure switch Niv.1 sensing failureE39Sensing failureE3AHeating element relay defect.E40Lid openE41Door is unlocked during the cycle (timeout 15 sec).E42Door lock defectE43Door lock triac defect.E44Door lock sensing failureE45Door lock triac sensing failureE50Motor triac short circuit.E51Motor triac short circuit.E52No signal from tachogenerator.E53Motor relay defect.E54Motor circuit interrupted.E55No signal from tachogenerator, no signal after 15 min.View all 92 error codes
E56Motor triac sensing failureE57Inverter current goes above threshold (>15A).E58Motor phase current goes above threshold (>4.5A).E59No tacho signal for 3 seconds after new speed target different from zero.E5AHeat sink temperature goes above threshold (88°C).E5BDC bus voltage goes below threshold (<175V).E5CDC bus voltage goes above threshold (>430V).E5DFCV cannot receive and/or transmit a message for more than 2 seconds.E5ECommunication problems between FCV control board and mainboard.E5FFCV control board is continuously asking for configuration parameters due to…E60Insufficient heatingE61Insufficient heatingE62OverheatingE66Heating element defectE68Leakage current in the appliance too high (insulation resistance < 168 kOhm).E70NTC defectiveE71NTC short circuit.E74NTC is not in the correct position in the tub.E80Wrong selector reset position detection.E82Wrong selector reset position detection.E83Wrong selector reading.E84Recirculation pump sensing failureE85Recirculation pump defect.E90Interrupted communication between In/Output electronic and main electronic.E91Interrupted communication between In/Output electronic and main electronic.E92Incongruence between In/Output electronic and electronicE93Configuration errorE94Loss of cycle dataE95Communication error between microprocessor and EEPROM.E96Incongruence between hardware version and cycles configuration.E97Incongruence between selector and cycles configuration.E98Incongruence between motor control board and electronic.E99Connection between loudspeaker and In/Output electronic defective.E9AFirmware between loudspeaker and In/Output electronic not ok.EA0DSP defectEA1DSP defect.EA2DPS sensing defect.EA3DPS unable to lock motor pulley.EA4DPS defectEA5Triac for DPS defect.EA6Drum has blocked in the first approx. 3 or 30 secondsEB0Power supply frequency out of limits.EB1Power supply frequency out of limits.EB2Power supply voltage too high.EB3Power supply voltage too low.EBELine Safe relay faulty.EBFLine Safe sensing faulty.EC0Inlet valve blocked.EC1Inlet valve blocked.EC2Turbidity sensor defect.EF0Filter dirtyEF1Filter dirtyEF2Detergent overdosingEF3Aqua Control system activatedEF4No signal from flow meter with electro valves switched onEF5Interrupted the spinning phaseEH0Power supply frequency out of limits.EH1Power supply frequency out of limits.EH2Power supply voltage too high.EH3Power supply voltage too low.EHELine Safe relay faulty.EHFLine Safe sensing faulty.
Service modes (8)
- Buzzer Activation/Deactivation1
- Cancel Last Alarm1
- Child Safety Activation/DeactivationKeep key 3 and key 2 pressed simultaneously until the LED is lit
- Demo Program1
- Electronic Test1. Switch off the appliance. 2. Hold buttons 4 and 3 pressed simultaneously and turn the program…
- Extra Rinse Activation/Deactivation (hidden)1
- Rapid Alarm Code ReadingKeep buttons 4 and 3 pressed together
- Service Test Program1
Full entry steps, exit procedures, and test sequences are available in Max.
Related AGA range models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass