Model reference
Amana CR5-3/P58372-40C
Air Conditioner
3 documents64 error codes39 service modes
Available documentation
Tech Sheet
- techsheet w10280489 revd48 pg
Tech Tip
- Instruction Sheet57 pg
- Instruction Sheet18 pg
MyPros+ Max
Diagnose your Amana CR5-3/P58372-40C.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (64)
CodeMeaning
BURNER HIGH LIMIT FAULTIndicates the temperature disk in the burner has opened (tumbler hi-limit has…BURNER IGNITION CONTROL FAULTNo signal to gas valve from Direct Spark Ignition (DSI) module during trial for…BURNER PURGE FAULTThe gas valve signal is present during the prepurge time.dSFLIndicates a loose connection on sensor probe wiring when power is reestablished…EE PROM FAULT ###Error in memory location; the ### indicates the location of the fault.EXHAUST HIGH LIMIT FAULTIndicates the temperature disk in the exhaust has opened.EXHAUST HIGH TEMP FAULTIndicates the temperature in the tumbler is above 220°F (104°C).F0 E0No fault codes stored in memory.F0 E2Over suds condition detectedF0 E4High water temperature detected during rinse cycle (105°F or higher).F0 E5Off balance load detected.F0E0No fault codes stored in memory.F0E2Over suds condition detected; suds prevent basket from spinning up to speed or…F0E4High water temperature detected (105°F or higher) during rinse cycle.F0E5Off balance load detected.F1 E1Main control fault.F1 E2Motor control faultF1E1Main control fault.F1E2Motor control fault on the main control board.F2 E1Stuck keyF2 E3Mismatch of Main Control and UIF2E1Stuck key; one or more keys on the User Interface were actuated for 15…F2E2Mismatch of main control and user interface; UI identification does not match…F2E3Mismatch of main control and User Interface; UI identification does not match…F3 E1Pressure sensor faultF3 E2Inlet water temperature faultF3E1Pressure sensor fault; main control detects an out of range pressure signal.F3E2Inlet water temperature fault; inlet thermistor detected to be open or shorted.F5 E1Lid switch faultF5 E2Lid lock faultView all 64 error codes
F5 E3Lid unlock faultF5 E4Lid not opened between cyclesF5E1Lid switch fault; lid is in locked state but lid switch is open.F5E2Lid lock fault; lid lock has not moved into locked position or motor cannot be…F5E3Lid unlock fault; lid lock has not moved into unlocked position or motor cannot…F5E4Lid not opened between cycles; user presses START after several consecutive…F7 E1Basket speed sensor faultF7 E5Shifter faultF7 E6Motor faultF7 E7Motor unable to reach target RPMF7E1Basket speed sensor fault; main control cannot determine speed of basket or…F7E5Shifter fault; main control cannot determine position of shifter.F7E6Motor fault; open clockwise or counterclockwise circuit of the motor.F7E7Motor unable to reach target RPM; basket speed sensor detects that target RPM…F8 E1No fill / long fillF8 E3Overflow conditionF8 E5Hot and cold water supply hoses are reversed.F8E1No fill or long fill; water level does not change for a period of time or water…F8E3Overflow condition; main control senses water level that exceeds the washer's…F8E5Hot and cold inlet hoses are reversed.F8E6No fillF9 E1Long drainF9E1Long drain; water level does not change after the drain pump is on for 10…FLAME FAULTFlame was detected during trial for ignition but failed sometime after; must…IGNITION FAULTGas valve did not remain open after trial for ignition; indicates that no flame…LINT ACCESS OPENIndicates the lint drawer is open and needs to be closed.LOW VOLTAGE FAULTIndicates power has dropped below the operating values and will shutdown.MAIN DOOR OPENEDA main door is open when it should be closed.MODEL ERROR, ENTER CORRECT MODELThe wrong model was selected for the dryer.OPEN EXHAUST TEMPERATURE PROBEIndicates the exhaust temperature probe is open or shorted.OPEN S.A.F.E. SYSTEM PROBE FAULTIndicates the temperature probe for the S.A.F.EROTATION FAULTIndicates the tumbler is not rotating.SAIL SWITCH CLOSED FAULTSail switch is closed when it should be open (prior to start up).SAIL SWITCH OPEN FAULTSail switch is open when it should be closed (opened during heating mode).
Service modes (39)
- Automatic Test Mode["Enter Diagnostic Test Mode.","Turn cycle selector knob until Spin LED is On (display shows '02'…
- automatic_test["Enter Service Diagnostic Test Modes.","Turn cycle selector knob until only the 'Spin' LED is…
- calibration["Enter Service Diagnostic Test Modes.","Turn cycle selector knob until only the 'Rinse' LED is…
- Calibration Mode["Enter Diagnostic Test Mode.","Turn cycle selector knob until Rinse LED is On (display shows '04'…
- Clean Washer Cycle["Activate Service Diagnostic Test Modes.","Toggle cycle selector knob until SOAK/WASH, RINSE, and…
- diagnostic["Ensure washer is in standby mode (plugged in with all indicators off).","RESET
- diagnostic (service diagnostic test modes entry)["Ensure washer is in standby mode (plugged in with all indicators off).","RESET
- Diagnostic Test Mode Entry["Ensure washer is in standby mode (plugged in with all indicators off).","RESET
- Drain and Spin Cycle["Activate Service Diagnostic Test Modes.","Toggle cycle selector knob until RINSE and DONE LEDs…
- Fault Code Display Mode["Enter Diagnostic Test Mode.","Turn cycle selector knob until Done LED is On (display shows '01'…
- fault_code_display["Enter Service Diagnostic Test Modes.","Turn cycle selector knob until only the 'Done' LED is…
- Manual Overview Test Mode["Activate Service Diagnostic Test Modes.","Toggle cycle selector knob until FINAL SPIN and DONE…
- Manual Test Mode["Enter Diagnostic Test Mode.","Turn cycle selector knob until Spin & Done LEDs are On (display…
- manual_test["Enter Service Diagnostic Test Modes.","Turn cycle selector knob until 'Spin' and 'Done' LEDs are…
- Quick Overview Test Mode["Activate Service Diagnostic Test Modes.","Toggle cycle selector knob until only the FINAL SPIN…
- S.A.F.E. System Check Procedure["Ensure dryer is in READY mode with no cycle loaded or in progress.","Ensure all water supply…
- Sales Demo Mode["Activate diagnostic test mode.","Turn cycle selector knob until Rinse & Done LEDs are On and…
- Service Diagnostic Mode Entry["Ensure washer is in standby mode (plugged in with all indicators off).","RESET
- Service Diagnostic Test Mode Entry["Ensure washer is in standby mode (plugged in with all indicators off).","RESET
- Service Diagnostic Test Modes (Entry)["Ensure washer is in standby mode (plugged in with all indicators off).","RESET
- Service Diagnostics - Step 00 (FC Thermistor)Enter Service Diagnostics Mode
- Service Diagnostics - Step 01 (RC Thermistor)Enter Service Diagnostics Mode
- Service Diagnostics - Step 02 (Evaporator Fan Motor)Enter Service Diagnostics Mode
- Service Diagnostics - Step 03 (Condenser Fan Motor)Enter Service Diagnostics Mode
- Service Diagnostics - Step 04 (Compressor)Enter Service Diagnostics Mode
- Service Diagnostics - Step 05 (Air Door & Evap Fan On)Enter Service Diagnostics Mode
- Service Diagnostics - Step 06 (Defrost Heater On)Enter Service Diagnostics Mode
- Service Diagnostics - Step 07 (Defrost Option)Enter Service Diagnostics Mode
- Service Diagnostics - Step 10 (Pan Accent Light)Enter Service Diagnostics Mode
- Service Diagnostics - Step 11 (Pan Thermistor)Enter Service Diagnostics Mode
- Service Diagnostics - Step 12 (User Selection LED Indicator Test)Enter Service Diagnostics Mode
- Service Diagnostics - Step 13 (Pan Air Door)Enter Service Diagnostics Mode
- Service Diagnostics ModeProduct must be on
- Software Version Display Mode["Enter Diagnostic Test Mode.","Turn cycle selector knob until Rinse, Spin, and Done LEDs are On…
- sw_version_display["Enter Service Diagnostic Test Modes.","Turn cycle selector knob until 'Rinse', 'Spin', and 'Done'…
- Tachometer Verification Mode["Enter Diagnostic Test Mode.","Turn cycle selector knob until Wash and Done LEDs are On (display…
- tachometer_verification["Enter Service Diagnostic Test Modes.","Turn cycle selector knob until 'Wash' and 'Done' LEDs are…
- UI Test Mode["Enter Diagnostic Test Mode.","Turn cycle selector knob until Rinse & Spin LEDs are On (display…
- ui_test["Enter Service Diagnostic Test Modes.","Turn cycle selector knob until 'Rinse' and 'Spin' LEDs are…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana air conditioner models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax