Model reference
Amana RF4,5H/P53802-5C
Air Conditioner
3 documents60 error codes25 service modes
Available documentation
Installation Guide
- Installation Instructions17 pg
- Installation Instructions17 pg
- Installation Instructions30 pg
MyPros+ Max
Diagnose your Amana RF4,5H/P53802-5C.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (60)
CodeMeaning
1c1cShorted key detected on the membrane keyboard.1c2cMembrane keyboard disconnected from the control board.1c4cBoard-to-board communication failure.1c6cEEPROM hardware fault.1c7cControl not calibrated.1c81EEPROM CRC error in Cook Profile data.1c8cEEPROM CRC error in User Options data.1d11Unlocked runaway oven temperature exceeding 600°F.1d21Locked runaway oven temperature exceeding 950°F.3d11Oven temperature sensor circuit is open.3d21Oven temperature sensor circuit is shorted.3d41Meat probe circuit is shorted.3d51Meat probe not calibrated.4d11Door switch not closed when door is locked.4d21No cooling fan rotation detected.4d31Cooling fan is on when it should be de-energized.4d41Cooling fan overspeed condition detected.4d51Door switch circuit fault.9d11Door latch will not lock.9d21Door latch will not unlock.9d31Door latch reports both locked and unlocked simultaneously.F1Internal board failure (LCC 90/95)F1.E1Relay Control Board defective.F1E0Internal board failure.F1E1Indicates a CCU (Cycle Control Unit) problem.F1E2Internal board failure.F2A/D Error(s)F2.H1Hood/light switch stuck.F2.H2Hood/light switch error.F2.Q1User interface board (UIB) is not reading keypad inputs.View all 60 error codes
F2E0Shorted key.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F3Oven sensor opened or shorted, or bake/broil/clean range over temperature (LCC…F3.H1Humidity sensor failure.F3.T1UIB (user interface board) thermistor failure.F3.T4Magnetron thermistor failure.F3E0Oven sensor opened.F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5Door and switches do not agree or door latch not operating during clean mode…F5E0Door and switches do not agree (clean mode).F5E1Door latch not operating (clean mode).F5E2Door and switches do not agree (clean mode).F6MW relay failure (Relay 4903 on Relay Board).F6E1Communication error from UI to CCU; communication between CCU and UI has not…F6E2Communication error from CCU to UI; communication between CCU and UI has not…F7Power to magnetron interrupted.F9Relay Control Board communications error.F9.QTouch communication error.F9E0Miswired house or miswired range.L2Low L2 voltage (less than 50V) detected at the CCU.PFPower failure occurred while the dryer was running.
Service modes (25)
- Control LockoutPress the Back and Setup pads simultaneously for 5 seconds to lock.
- Control Reset1
- control_lockoutPress the Back and Setup pads simultaneously for 5 seconds to lock.
- control_reset1
- Customer-Focused Dryness Level Adjustment1
- Demo Mode1
- Diagnostics ModePress CANCEL > CANCEL > START within a 5-second period.
- Diagnostics Test Mode (Relay Checks)While in Diagnostics Mode, press individual keypads to test control relays
- Display Test1
- display_test1
- Electronic Oven Control Test["1. Unplug the oven.","2. Remove the cabinet.","3. Discharge the HV capacitor with a 20,000 ohm…
- Faults Access1
- faults_access1
- Install Diagnostics1
- Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
- Quick Test Mode (EOC III)1
- quick_test1
- Service Diagnostic Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Select any three buttons…
- Service Mode1
- service_mode1
- Software Version Display1
- Software Versions Access1
- software_versions_access1
- Temperature Adjustment ModeStep 1
- Touch Panel Test Mode["1
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana air conditioner models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass